INSTRUCTION MANUAL VOSS.FARMING SUNNY 800
15
TROUBLESHOOTING TIPS FROM OUR EXPERTS
TIP 1: TEST THE ENERGISER (FIG. 1)
1. Remove the nuts from the fence and ground terminals.
2. Hold the grounding rod of a fence tester against the energiser's ground terminal.
3. Now touch the fence tester against the energiser's fence terminal. You should
have the voltage over 6000 V. Measurements should only be done with 2‑pole
fence testers (with an earth rod). Do not use 1‑pole fence testers!
TIP 2: CHECK FENCE SUPPLY LINE
1. Switch off the energiser.
2. Disconnect the fence connection cable from the fence.
3. Switch the energiser on again and measure on the fence connection cable
directly. (Here the voltage should be almost identical to the voltage directly on the
energiser).
TIP 3: CHECK GROUNDING (FIG. 2)
How do I measure the voltage directly on the earth rod?
1. Short‑circuit the fence wire to the ground at a distance of approx. 10m from the
grounding (e.g. using the iron rods).
2. Now put the fence tester grounding rod between the 2 points and measure the
voltage directly on the grounding rods. (The voltage should not exceed 1000V) If
there is already voltage on the grounding without iron rods, this must be improved.
Fig. 1
TIP 4: POWER SUPPLY
1. 9V energisers: battery voltage should be between 4 – 9 V.
2. 12V energisers: battery voltage should be above 11.4 V. Under 11 V deep discharge
possible.
3. 230V energisers: energisers must blink, if necessary try on another power outlet
(no blinking = defective).
DO NOT USE INVERTERS WITH 230V DEVICES!
42088 | 01 | 2021 | V3