RainSoft TC Serie Manual De Usuario página 11

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

12.
Install the Brine Line
• Slide the brass compression nut over the end of the brine line,
followed by the ferrule and tube support. Attach the brine line to
the brass fitting on the right side of the valve (see figure 7).
• Insert a tube support into the other end of the brine line and
push the brine line into the brine safety float elbow. Use a
locking clip to secure the connection (see figure 7).
13.
Install the Brine Overflow Line (Indoors)
• Run a 1/2 inch I.D. brine overflow line from the overflow elbow
on the side of the brink tank to an approved drain (see figure 7).
SECONDARY OVERFLOW
SECONDARY OVERFLOW
LINE CONNECTION
LINE CONNECTION
14.
Attach the Electrical Connection
• Remove the supplied wire from the warranty pack.
• Attach the U shaped connectors (supplied) to the wire with a
crimping tool (not supplied). Then connect the wire to the two
outside terminals on the transformer (see figure 8).
• Insert the other end of the wire, with the quick connector, into
the back of the control box (see figure 8).
• Plug the transformer into a 110 VAC 60 Hz or 230 VAC 50 Hz
outlet.
SHRINK TUBING
18/2 GAUGE WIRE
TRANSFORMER
Figure 7
Figure 8
CONTROL BOX
QUICK CONNECTOR
CONNECTORS
U-SHAPED CONNECTORS
POWER CORD
Important Note: Not Applicable for
TC-CAB Models.
Important Note for TC-CAB
Models: The overflow elbow is
located on the back of the brine
tank (not shown).
Important Note: The brine over-
flow line must not be higher than
the overflow elbow on the brink
tank. (This is a gravity overflow.)
And only is used when other over-
flow valves fail.
Helpful Tip: If the wire is too
short, use the supplied connec-
tors and shrink tubing in the
warranty pack to lengthen the
wire.
Helpful Tip: Squeeze the
connector to release it from the
box.
Helpful Tip: Check the transformer
label for the correct voltage
requirement.
11

Capítulos

Tabla de contenido
loading

Tabla de contenido