Photocell testing
Opening photocells (SG.A): place DIP6 in
ON to enable testing.
Closing photocells (SG.C): place DIP9 in ON
to enable testing.
STOP pushbutton enabled (emergency stop): DL1 and DL3 flash simultaneously every 0.5 seconds.
Opening or closing photocell testing error: DL1 and DL3 flash simultaneously every 2 seconds.
PWR LED
(AUL05/AUL06)
10
General connections
ST2
ST1
LED
(AUL05 / AUL06)
V+
COM
N
L
P289Y
SG.A
(photocells without testing)
(photocells with testing)
230V, máx. 60W
N
L
Encoder
For the correct operation of the
encoder, ensure DIP7 is in ON.
LED strip connections
The LED strip is an optional accessory which can be bought
separately. It includes: a traffic light card (SMF), a power source
(PWR LED), an LED strip (LED) and the cables and glands
necessary.
There are two references:
• AUL09: for 3m barriers
• AUL05: for 4.5m barriers.
• AUL06: for 6m barriers.
The "Transparent rubber" accessory MUST be installed in
order to install the LED strip.
This rubber is supplied separately, in lengths of 6m (AUL03),
4.5m (AUL04) and 3m (AUL08).
F1 Motor fuse (5x20):
230VAC: 2,5A
125VAC: 6,3A
F2 Electronic fuse
(5x20; 230VAC: 500mA)
F3 FT and AUX24V outputs fuse
(5x20; 315mA)
FCA
DL1 Barrier open
DL2 Radio code programming
indicator / Receiving radio
code
FCC
DL3 Radio code or operation
programming
DL4 Opening relay enabled
DL5 Closing relay enabled
DL6 Opening limit switch contacts
closed
DL7 Closing limit switch contacts
closed
DL8 Opening safety device
contacts closed
DL9 Closing safety device contacts
closed
DL10 Pedestrian key command
contacts closed
DL11 Total key command contacts
closed
DL12 Radio key command
DL13 Encoder signal
Operator working: DL13
comes on intermittently,
since the encoder sends the
signal in the form of pulses.
Operator shutdown: DL13
may be on or off, indistinctly,
P289Z
depending on the position of
the encoder (high pulse or
low pulse).
DL14 Power supply