open gate detector (SCA)
+ -
24V
5W
common
The current feed line (230V L,N,
gnetometric switch or a pair of 5A fuses. A differential switch is recommended but not
neccessary if it is already found at the top of the system.
Feed the device with a 3x1,5mm
en the board and the connection to the grounding system exceeds 30m it is necessary to
provide an earth plate near the control board.
Cabling must be done when the control board is switched off.
Input of N.C. type contacts (normally closed), if they are not used, must be bridged with
an ordinary terminal (+24V). If there are more N.C. contacts for the same input they must
be placed in series (example: ph1 and ph2 in the diagram).
Inputs of N.O. type contacts (normally open), if not used, must be left free. If there are
more N.O. contacts for the same input they must be placed in parallel (example: st1 and
st2 in the diagram).
20
electric lock
+ -
24V
0.5A
12V
10W
common
start
stop
photocell in
closing
2
cable (phase+neutral+ground). If the distance betwe-
WARNING: Connect the
encoder to the board
keeping to the colours of
the cables as shown
+ -
24V
mot1 mot2
25W
fl asher
pedestrian
photocell in
opening and
in closing
) to the automation must be protected by a ma-
LINE
L N
T
1,25A