DeLonghi P60 Instrucciones Para El Uso página 42

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
IMPORTANT: Installation has to be carried out according
to the instructions provided by the manufacturer.
Incorrect installation might cause harm and damage to
people, animals or objects, for which the manufacturer
accepts no responsibility.
DETAILS
Connection to the electric power supply must be carried out by
a qualified technician and following the appropriate safety reg-
ulations;
Before carrying out the connection to the power supply, the
voltage rating of the appliance (stamped on the appliance iden-
tification plate) must be checked for correspondence to the
available mains supply voltage, and the mains electric wiring
should be capable of handling the appliance's power rating
(also indicated on the identification plate);
If the appliance is supplied without a power supply plug and if you
are not connecting directly to the mains, a standardized plug suit-
able for the load must be fitted.
The power point must be connected to a suitable earth wiring,
in conformity to current safety regulations.
The colours of the wires in the hob power cable may not cor-
respond with the colours marked on the terminals of your elec-
trical plug. The plug should in any case be wired as follows:
– connect the green/yellow wire to the terminal marked with
the letter PE or the earth symbol or coloured green/yellow;
– connect the blue wire to the terminal marked with the letter
N or coloured black;
– connect the brown wire to the terminal marked with the letter
L or coloured red.
It is possible to connect the appliance directly to the mains sup-
ply by means of a heavy duty switch with 3 mm minimum dis-
tance between the contacts.
The power supply cord must not touch against any hot sur-
faces and must be placed so that its temperature does not
exceed 75°C at any point along its length.
After having installed the appliance, the power switch or power
plug must always be in a accessible position.
The appliance must have its own supply; any other appliances
installed near it must be supplied separately.
– N.B. For connections to the mains power supply, never use
adaptors, reductions or multiple power points as these may
overheat and catch fire.
In the event that installation should require modifications to the
mains supply wiring system, it is recommended that a qualified
technician be called to carry out substitution.
The technician will also have to verify that the cross-section of
the electric cables on the power point match the appliance's
power rating.
Before carrying out any work on the electrical section of
the appliance, it must be disconnected from the mains.
42
Gas models or gas/electric models
for the OTHER COUNTRIES
Connection to a good earth wiring system is absolutely
essential.
The manufacturer accepts no responsibility for any
inconvenience caused by failure to comply with this rule.
FEEDER SPECIAL CABLE SECTION
Type "HO5V2V2-F"
resistance to temperatures of 90°C
230 VAC 50/60 Hz
3 x 0,75 mm
230 VAC 50/60 Hz
3 x 1 mm
Replacing the power cord
The supply cable must be replaced with a cable of the same
type.
The electrical cable must be connected to the terminal board fol-
lowing the diagrams of fig. 6.4.
230 V
L1
Fig. 6.4
2
2
(for models with a rating of
1,5 kW at 230 V)
PE
N(L
)
2
Tabla de contenido
loading

Este manual también es adecuado para:

P90

Tabla de contenido