Nail
NOTE:
Ensure the point of nail stick to be ridden in the bottom of maga-
zine.

TEST OPERATION

1
Adjust the air pressure at 5 bar (70p.s.i.) and connect the air
supply.
2
Without touching the trigger, depress the contact arm
against the work-piece.
Pull the trigger (The tool must fire the fastener.)
3
With the tool off the work-piece, pull the trigger.
Then depress the connect arm against the work-piece. (The
tool must fire the fastener when you select contact actua-
tion.)
4
Adjust the air pressure as much as the lowest possible ac-
cording the length of fastener and the hardness of work
piece.
AIR HOSE CONNECTION
Connect the air chuck to the air plug.
WARNING
When connecting the air chuck, do not point the nail dis-
charge outlet at any part of your body or at another person,
and do not touch the trigger.

DRIVING FASTENERS

NOTE :
This tool is shipped with SEQUENTIAL TRIP selected.

SEQUENTIAL TRIP

The Sequential Trip requires the operator hold the tool against
the work before pulling the trigger.
This makes accurate fastener placement easier, for instance on
framing, toe nailing and crating applications.
The allows exact fastener location without the possibility of driving
a second fastener on recoil, as described under "Contact Trip".
The Sequential Trip Tool has a positive safely advantage be-
cause it will not accidentally drive a fastener if the tool is contact-
ed against the work or anything else-while the operator is holding
the trigger pulled.
Gap
Gap
Switching SEQUENTIAL TRIP to CONTACT TRIP
WARNING
ALWAYS disconnect air supply before switching the trigger-
ing method.
Button
1
Press the button on the trigger.
2
Turn the switching lever in the direction of the arrow.
3
Set the switching lever as above picture.
9
Switching lever
Switching lever