Astralpool V-HEAT Serie Manual De Instrucciones página 28

Bomba de calor para piscina
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

V-HEAT SERIES · AIR/WATER SYSTEM
Operation Data Settings
The unit's operation data can be set on the whire controller. Please set according the below table:
Digit
Return water temp.
00
Setting(cooling mode)
Return water temp.
01
Setting(heating mode)
Turn round of dehumidifying
02
under heating mode(frost)
*03
Defrosting start temperature
Terms of exit defrost under
04
heating model
Time of exit defrost under heating
05
model
*06
System quantity
*07
Automatic restarting
Model(cooling only/heat
08
pump/auxiliary electrical
heating/hot water)
*09
Water pump model
Note: Above data setting 00 is relevant to cooling mode only. All other data (ie 01-08) is relevant to heating mode.
Remarks:
Parameter 03:
The wire controller displays (0 - 30ºC), but the actual range is (-30 - 0ºC).
The default 7ºC is -7ºC actually.
Parameter 06:
1: the unit has 1 system;
2: the unit has 2 systems;
Parameter 07:
0: the unit can restart automatically;
1: the unit can not restart automatically;
© ASTRALPOOL 2018. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Meaning
Range
Default
8-28
15-40
30-90 min
0-30
0-30
1-12MIN
1-2
0-1
0 (NO) / 1 (YES)
0/1/2/3
0/1
ENGLISH
Adjust (yes/no)
27
yes
27
yes
45 min
yes
7
yes
13
yes
8MIN
yes
1/2
Do not Modify
0
yes
0
yes
0
yes
Page 28 of 72
Tabla de contenido
loading

Tabla de contenido