AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email :
[email protected]
General Features
General Features
Three-phase power circuit (U/V/W)
TPD32 EV-500/... :
230 V
±10%, 50/60Hz ±5%
AC
400 V
±10%, 50/60Hz ±5%
AC
440 V
±10%, 50/60Hz ±5%
AC
460 V
±10%, 50/60Hz ±5%
AC
480 V
±10%, 50/60Hz ±5%
AC
500 V
±10%, 50/60Hz ±5%
AC
2 quadrant (..-2B): from 20A up to 3300A
4 quadrant (..-4B): from 20A up to 3300A
TPD32 EV-575/... (*):
230 V
±10%, 50/60Hz ±5%
AC
400 V
±10%, 50/60Hz ±5%
AC
440 V
±10%, 50/60Hz ±5%
AC
460 V
±10%, 50/60Hz ±5%
AC
480 V
±10%, 50/60Hz ±5%
AC
500 V
±10%, 50/60Hz ±5%
AC
575 V
±10%, 50/60Hz ±5%
AC
2 quadrant (..-2B): from 280A up to 2300A
4 quadrant (..-4B): from 280A up to 2300A
TPD32 EV-690/... (*):
230 V
±10%, 50/60Hz ±5%
AC
400 V
±10%, 50/60Hz ±5%
AC
440 V
±10%, 50/60Hz ±5%
AC
460 V
±10%, 50/60Hz ±5%
AC
480 V
±10%, 50/60Hz ±5%
AC
500 V
±10%, 50/60Hz ±5%
AC
575 V
±10%, 50/60Hz ±5%
AC
690 V
±10%, 50/60Hz ±5%
AC
2 quadrant (..-2B): from 560A up to 3300A
4 quadrant (..-4B): from 560A up to 3300A
TPD32 EV-CU-230/500-...:
230 V
... 500 V
±10%, 50/60Hz ±5%
AC
AC
TPD32 EV-CU-575/690-...:
575 V
... 690 V
±10%, 50/60Hz ±5%
AC
AC
TPD32 EV-FC-200/...:
60 V
... 200 V
±10%, 50/60Hz ±5%
AC
AC
TPD32 EV-FC-500/...:
230 V
... 500 V
±10%, 50/60Hz ±5%
AC
AC
Single-phase field circuit (U1/V1) (*)
230 V
±10%, 50/60Hz ±5%
AC
400 V
±10%, 50/60Hz ±5%
AC
460 V
±10%, 50/60Hz ±5%
AC
Single-phase regulation circuit (U2/V2)
115 V
±15%, 50/60Hz ±5%
AC
230 V
±15%, 50/60Hz ±5%
AC
P R O F I
PROCESS FIELD BUS
B U S
Field bus and
serial protocol
8
Standard supply configuration
• Speed feedback via tachogenerator and/or digital or sinusoidal encoder;
• Digital I/O logic control in PNP and/or NPN configuration;
• Analog inputs: 3 Differential, 12 programmable Bits, selectable for ±10 VDC, 0-20mA, 0-10
VDC, 4-20mA;
• 2 Analog outputs (±10Vdc);
• 2 encoder inputs: sinusoidal (power supply at 5 V) and digital (power supply at 24 V);
• 1 Tachogenerator input;
• 8 Digital inputs (4 fixed + programmable);
• 4 programmable digital outputs;
• Relay outputs: 1 Drive OK normally closed contact, 1 programmable normally closed contact;
• 1 Motor thermistor input;
• RS485 Serial line (Modbus RTU protocol);
• Programmable overload up to 200%;
• Interfacing with fieldbus protocol as: ProfibusDP , CANopen and DeviceNet;
• LED diagnostics module.
Integrated System Technology
• Quick start up;
• Autotuning of the speed and current regulators (*);
• 5 Independent programmable Multi-ramps;
• Programmable Linear and "S"shaped ramps;
• Seven Programmable Multispeeds;
• Independent regulation of the Min/Max speed for each direction sense of rotation;
• Current limitation in accordance with the speed;
• Adaptive gains of the speed regulator;
• Independent management of the integral gain at zero speed;
• Programmable overload control;
• Jog function;
• Motorpotentiometer function;
• I
t motor protection;
2
• PID function block;
• Servodiameter control function;
• "Speed Draw" function;
• "Autocapture" function (Flying restart);
• "Droop" function.
Options
- Programming keypad KB;
- I/O expansion card TBO-32;
- Profibus interface SBI-PDP-32;
- DeviceNet interface SBI-DN;
- CANopen interface SBI-COP;
- Programmable application card APC300;
- Supplementary encoders management DEII.
Accessories
- Dedicated EMC filters (in accordance with EN61800-3);
- Input choke (standardised for the whole line);
- Programming remote keypad kit;
- RS485 serial line kit for direct PC communication,
Environmental conditions
Protection degree:
IP20 up to 1000A (..-2B) and 1050A (..-4B)
IP20/IP00 for bigger powers.
Operating temperature:
from 0°C (32°F) to 40°C (104°F), from + 40°C (104°F) to +50°C (122°F)
with derating.
Storage temperature:
-25°C...+55°C (13°F to 131°F), Class 1K4 – EN50178
Humidity:
from 5% to 85%, relative humidity (without condensation) or ice
formation (Class 3K3 under EN50178).
Altitude:
up to 1000 metres above sea level; above this level the current must
be reduced by 1.2% per 100 metre increase.
Standards and Marks
CE:
complies with the EEC directive concerning low voltage equipment.
UL, cUL:
complies with directives for the American and Canadian market (TPD32
EV-...-NA series).
EMC:
complies with the EEC directive - EN 61800-3 concerning
electromagnetic compatibility with the use of optional filters.
(*) Except the TPD32-EV-FC-... series