WIRING KITS - SOLTRANS88
Installation
Connect the supplied quick-connect pigtail
to the power outlet on the back of the
transformer. Loosen the screws on the
outlet terminals and slide the spade
connectors on the pigtail under the
screw plate. Tighten the screws to
secure the spade connectors.
Mount the Transformer in the desired location.
The Transformer is weather resistant and must
be mounted above the ground on a wall or post.
Ensure that the power cord is within reach of a properly
grounded Ground Fault Circuit Interrupter (GFCI) outlet.
After all connections to low voltage lights have been completed, plug the input power cord
into the 120 volt GFCI outlet to complete installation.
Operation
The SOLTRANS88 has an easily
understood control panel
featuring a rotary timer control
switch, photocell and circuit
breaker / reset button.
The circuit breaker will turn off
power to the lighting system in
to case of overload / power surge.
If the circuit is tripped, inspect / repair
the lighting system and depress the reset
button to restore power. The photocell
automatically turns the transformer on
when it begins to get dark outside. The
photocell does not need to be in contact with direct sunlight; however it must have access to
indirect sunlight to operate effectively.
The timer switch provides several modes of operation. You can choose OFF, ON, AUTO, 4H, 6H,
or 8H.
OFF: Output power is off / system is off
ON: Output power is on / system is on at all times
AUTO: Photo cell will turn the output power on at
dusk and off at dawn
4H: Photo cell will turn the output power on at
dusk and it will turn off after 4 hours
6H: Photo cell will turn the output power on at
dusk and it will turn off after 6 hours
8H: Photo cell will turn the output power on at
dusk and it will turn off after 8 hours
6
Spade
Connectors
Outlet Power
Terminals
Circuit Breaker / Reset Button
Photocell Sensor
Timer Control
Input Power Cord
4H
6H
8H
AUTO
ON
OFF