Compressor Stop-Start Delay Parameter ( Default = 0) MODBUS ADRES:40010
When compressor is inactive, this time delay must be expired for activation of the
compressor. It can be adjusted from 0 to 20 minutes.
Compressor Start-Start Delay Parameter
This time delay must be expired between two activation of the compressor. It can be
adjusted from 0 to 20 minutes.
Sensor Defect Parameter ( Default = 0 ) MODBUS ADDRESS:40012
Compressor is OFF in case of sensor defect.
Compressor is ON in case of sensor defect.
Compressor operates periodically according to
case of sensor defect.
Compressor is active during this time period in case of probe defect (Default = 0)
MODBUS ADDRESS:40013
If probe defect parameter
0 to 99 minutes.
Compressor is inactive during this time period in case of probe defect
( Default = 0 ) MODBUS ADDRESS:40014
If probe defect parameter
0 to 99 minutes.
Alarm Type Selection Parameter ( Default = 2 ) MODBUS ADRESS:40015
Sensor Break Alarm
Process High Alarm
Process Low Alarm
Deviation High Alarm
Deviation Low Alarm
Deviation Band Alarm
Deviation Range Alarm
Alarm Set Value Low Limit Parameter ( Default = Minimum Value of Device Scale)
MODBUS ADDRESS:40016
Alarm set value can not be lower than this value.This parameter value can be adjusted
from
minimum process set value parameter to alarm set value high limit parameter
value.
Alarm Set Value High Limit Parameter ( Default = Maximum Value of Device Scale)
MODBUS ADDRESS:40017
Alarm set value can not be greather than this value.This parameter value can be
adjusted from
alarm set value low limit parameter value to maximum process set value
parameter.
Alarm On Delay Time
It can be adjusted from 0 to 999 minutes.
Alarm Off Delay Time
It can be adjusted from 0 to 99 minutes.When this parameter is 99, if increment button is
pressed,
is observed and alarm latching output is selected. To make the alarm latching
output passive,decrement button must be pressed in main operation screen.
Alarm Delay Parameter After Power On
This parameter defines the delay for the alarm is being active after power on.It can be
adjusted from 0 to 99 minutes.
Alarm Set Value Parameter
Alarm output is controlled according to this value.For alarm type selection paramater
=1 or 2,this parameter value is can be adjusted from alarm set value low limit
parameter to alarm set value high limit
=3,4,5 or 6 this parameter value is can be adjusted from 0 to alarm set value high limit
parameter.
Alarm Hysteresis Parameter
Alarm hysteresis value.
is 2, then this parameter is observed. It can be adjusted from
is 2, then this parameter is observed. It can be adjusted from
Parameter( Default = 0 ) MODBUS ADDRESS:40018
Parameter( Default = 0 ) MODBUS ADDRESS:40019
( Default = 0 ) MODBUS ADDRESS:40020
( Default = 20 ) MODBUS ADDRESS:40021
( Default = 0 ) MODBUS ADDRESS:40022
This parameter is can be adjusted 0 to %50 of the device scale.
( Default = 0) MODBUS ADRES:40011