Fein SCT5-40X Manual De Instrucciones página 13

Ocultar thumbs Ver también para SCT5-40X:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
OBJ_BUCH-0000000011-002.book Page 13 Thursday, January 13, 2011 11:33 AM
For your safety.
Read all safety warnings and all
WARNING
instructions. Failure to follow the
warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
Do not use this power tool before you have thor-
oughly read and completely understood this
Instruction Manual and the enclosed "General
Safety Instructions" (document number
3 41 30 054 06 1). The documents mentioned should be
kept for later use and enclosed with the power tool,
should it be passed on or sold.
Please also observe the relevant national industrial safety
regulations.
Intended use of the power tool:
hand-guided screwdriver for screwing in and unscrewing
screws, especially for drywall screws, in weather-pro-
tected environments using the application tools and
accessories recommended by FEIN.
This power tool is also suitable for use with AC genera-
tors with sufficient power output that correspond to the
Standard ISO 8528, design type G2. This Standard is par-
ticularly not complied with when the so-called distortion
factor exceeds 10 %. When in doubt, please refer to the
generator instruction/specification guide.
Special safety instructions.
Hold power tool by insulated gripping surfaces, when
performing an operation where the fastener may contact
hidden wiring or its own cord. Fasteners contacting a
"live" wire may make exposed metal parts of the power
tool "live"" and could give the operator an electric shock.
Beware of any concealed electric cables, gas or water
conduits; check the working area with a metal detector,
for example, before commencing work.
Secure the workpiece firmly. A work piece that is gripped
tightly in a clamping device or vice, is more secure than if
held by hand.
Hold the power tool firmly. High reaction torque can
briefly occur.
Do not machine any material containing asbestos. Asbes-
tos is cancerogenic.
Do not rivet or screw any name-plates or signs onto the
power tool. If the insulation is damaged, protection
against an electric shock will be ineffective. Adhesive
labels are recommended.
Do not use accessories which are not specifically
designed and recommended by the power tool manufac-
turer. Safe operation is not ensured merely because an
accessory fits your power tool.
Clean the ventilation openings on the power tool at regu-
lar intervals using non-metal tools. The blower of the
motor draws dust into the housing. An excessive accu-
mulation of metallic dust can cause an electrical hazard.
Before putting into operation, check the mains connec-
tion and the mains plug for damage.
Recommendation: The tool should always be supplied
with power via a residual current device (RCD) with a
rated current of 30 mA or less.
Hand/arm vibrations
The vibration emission level given in this information
sheet has been measured in accordance with a standard-
ised test given in EN 60745 and may be used to compare
one tool with another. It may be used for a preliminary
assessment of exposure.
The declared vibration emission level represents the
main applications of the tool. However if the tool is used
for different applications, with different accessories or
poorly maintained, the vibration emission may differ.
This may significantly increase the exposure level over
the total working period.
An estimation of the level of exposure to vibration
should also take into account the times when the tool is
switched off or when it is running but not actually doing
the job. This may significantly reduce the exposure level
over the total working period.
Identify additional safety measures to protect the opera-
tor from the effects of vibration such as: maintain the tool
and the accessories, keep the hands warm, organisation
of work patterns.
Operating instructions.
Adjust the Rotation selector switch only when the
machine is at a complete stop.
SCT5-40X/SCT5-40M/SCT6-25: The screwdriving applica-
tions are to be carried out with mounted depth stop.
SCT5-40M/SCT5-40UM: The collated cartridge may only
be operated in "clockwise-rotation direction" position.
Setting the torque (SCT5-40UX/SCT5-40UM)
(see page 5)
The factory setting is for the small to mid-size screw
range.
The tightening torque also depends on the force with
which the power tool is pressed against the screw.
Repair and customer service.
When working metal under extreme operat-
ing conditions, it is possible for conductive
dust to settle in the interior of the power tool.
The total insulation of the power tool can be impaired.
Blow out the interior of the power tool via the ventila-
tion slots frequently with dry and oil-free compressed air,
and connect a residual current device (RCD) on the line
side.
If the supply cord of this power tool is damaged, it must
be replaced by a specially prepared cord available through
the FEIN customer service centre.
If required, you can change the following parts yourself:
Application tools, depth stop, hand strap, magazine
Warranty and liability.
The warranty for the product is valid in accordance with
the legal regulations in the country where it is marketed.
In addition, FEIN also provides a guarantee in accordance
with the FEIN manufacturer's warranty declaration.
The delivery scope of your power tool may include only
a part of the accessories described or shown in this
instruction manual.
en
13
loading