PRECAUTIONS (cont...)
1 - GENERAL REMARKS (cont...)
- Before applying any aggressive
chemicals, please consult your dis-
tributor to confirm compatibility
with the dosing pump.
- All assembly should be done
without tools, hand tighten only.
2 - WATER WITH HIGH PARTICLE
CONTENT
- A (ex.: 300 mesh - 60 microns depen-
ding on your water quality) water
filter must be installed upstream from
the DOSATRON (see accessories), if a
filter is not installed abrasive substan-
ces will cause the DOSATRON to
deteriorate prematurely.
3 - WATER-HAMMER / EXCESSIVE
FLOW
- For installations subject to water
hammer a protection device such as
a check valve or union ball check
must be fitted (pressure/flow
control system).
- For automatic installations, slow
opening and closing solenoid valves
are preferable.
- In an installation where a
DOSATRON serves several sectors, the
closing of one sector and the opening
of another sector must be done at the
same time (simultaneous operation of
the solenoid valves).
©
DOSATRON INTERNATIONAL / 36
4 - INSTALLATION LOCATION
- The location of the DOSATRON and
concentrate container should be
accessible, but should never present
a risk of pollution or contamination.
- It is recommended to label all
water lines with a warning about
the injected solution i.e. Not For
Human Consumption.
5 - MAINTENANCE
- Rinse the injection areas after using
the DOSATRON. To do this, insert suc-
tion tube into a container of clean
water and inject about 1/4 liter
[8 1/2 US Fl.oz].
- Routine maintenance once a year
will add to the life of your DOSATRON.
Change the dosing seals at least once
a year, depending on its use.
6 - SERVICE
- This DOSATRON was tested prior to
packaging.
- Complete maintenance and seal
kits are available.
- Call your DOSATRON distributor for
service or parts.

ASSEMBLING THE DOSATRON

ASSEMBLY SHOULD BE CARRIED
OUT WITHOUT THE USE OF TOOLS
The DOSATRON is delivered with :
- a mounting bracket,
- a suction tube with a strainer.
- 1 by-pass tube ø 6 x 9 [1/4" ID
x 3/8" OD]
The bracket enables the DOSATRON
to be fixed to a wall.
- Slide dovetails on the pump body
(Fig. 1-A) into the support bracket
(Fig. 1-S).
- Remove the nuts (Fig. 1-E) and fer-
rules (Fig. 1-C) from the DOSATRON
inlet and outlet.
E
C B G J
©
DOSATRON INTERNATIONAL / 37
- Remove the plastic caps (Fig. 1-B)
which block the inlet and outlet of
your DOSATRON before connecting
to the water supply.
- Make sure the watertight seals at
the inlet and outlet of the DOSA-
TRON are correctly positioned : first
position the <O> ring (Fig. 1-J) and
then the spacing ring (Fig. 1-G).
- Make certain that the water flows
in the direction of the arrows on the
pump body.
S
A
Fig. 1
B
Tabla de contenido