Genio 050973 Manual De Instrucciones página 20

Lijadora electrónica orb. ø5/ø2,5 mm
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Manual EN
5. CONVENIENT ERROR RESOLUTION AND MAINTENANCE
Keep your power tool revised by a qualified repair
person and use only replacement
parts of original manufacturer.
This will ensure that the safety of the power tool
is maintained.
Abnormal signal
One long & one short flash
One long & two short flash
One long & three short flash
One long & four short flash
One long & five short flash
One long & six short flash
One long & seven short flash
One long & eight short flash
NORMAL TROUBLESHOOTING
Abnormity
No flash and operation after start
Excessive vibration
Abnormal noise while working
Lever abnormality
20
Abnormity
Motor operating abnormally
Motor electric current abnormity
PCB temperature abnormity
Motor phase failure
Input low voltage abnormality
Input high voltage abnormality
Programs of circuit board
abnormality
Motor temperature abnormality
ABNORMAL SIGNAL TROUBLESHOOTING
It is an abnormity when the LED indicator shows flash "red
and green" color. To acknowledge about the abnormity,
please follow the instructions below: Press —button hold
for five seconds, the LED indicator shows flash "red" color.
Solution
Motor failure. Please contact a qualified
repair person.
Motor failure. Please contact a qualified
repair person.
Please turn off the tool for a while. Restart the
tool after cooling.
If it is still failure after restart, please contact
a qualified repair person. Motor failure.
Please contact a qualified repair person.
Please check if the voltage is too low.
Please check if the voltage is too high.
Circuit board failure. Please contact a
qualified repair person.
Please turn off the tool for a while. Restart
the tool atfer cooling. If it is still failure after
restart, please contact a qualified repair
person.
Solution
Please check if the plug is inserted successfully or voltage
abnormality.
Please check if the pad is out of shape and need to be
changed.
Please stop using the tool. Please check if the spare parts
are damaged, or contact a qualified repair person.
Se��ng route program failure. Please reset the program by
following reset procedure.
Tabla de contenido
loading

Productos relacionados para Genio 050973

Este manual también es adecuado para:

050865

Tabla de contenido