TECHNICAL dATA

D112 MKII

D40

C430

DRUM SET CONCERT I MANUAL
7
Technical data
7.1
D112 MKII
Type:
Polar pattern:
Frequency response:
Recommended load impedance:
Sensitivity:
Max. SPL for 0.5% THD:
7.2
D40
Type:
Polar pattern:
Frequency response:
Recommended load impedance:
Sensitivity:
Max. SPL for 0.5% THD:
7.3
C430
Type:
Polar pattern:
Frequency response:
Recommended load impedance:
Sensitivity:
Max. SPL for 0.5% THD:
Phantom powering:
This product conforms to the standards listed in the Declaration of
Conformity. You can request the Declaration of Conformity by e‑mail from
large diaphragm dynamic micro‑
phone
cardioid
20 Hz to 17 kHz
≥ 2000 ohms
1.8 mV/Pa
>160 dB SPL
dynamic microphone
cardioid
75 Hz to 17 kHz
≥ 2000 ohms
2.2 mV/Pa
156 dB SPL
1/2" diaphragm, true condenser
pressure‑gradient microphone
cardioid
20 Hz to 20 kHz
≥ 2000 ohms
7 mV/Pa
126 dB SPL
48 V ± 4 V to IEC 61938