11. SPECIFICATIONS
Microphone Element
Modulation
Frequency Range
Channel Selectable
RF Carrier Power
Tone Frequency
Oscillator
Maximum Input Level
Maximum Deviation
Audio Frequency Response
Dynamic Range (AF Circuit)
Battery
Battery Life
Indicator
Antenna
Operating Temperature
Operating Humidity
Finish
Dimensions
Weight
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Microphone holder (with stand adapter) ............... 1
Screwdriver for setting (housed in the body) ........ 1
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the
antenna or the device is permitted. Any change to the antenna or the device could result in the device
exceeding the RF exposure requirements and void user's authority to operate the device.
License requirement
The term "IC:" before the radio certification number only signifies that Industry Canada Technical
specifications were met. Operation is subject to the following two conditions;
(1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
4
Dynamic microphone unit: Unidirectional
Frequency modulation
576 – 865 MHz (576 – 606 MHz and 614 – 698 MHz for USA/Canada)
64 channels (the number of channels may differ from country to country.)
Less than 50 mW (Factory preset 10 mW ERP)
32.768 kHz
PLL synthesized
142 dB SPL
±40 kHz
80 Hz – 15 kHz
95 dB or more (with WT-5800)
AA alkaline dry cell battery
Approx. 10 h (when the alkaline battery is used)
Power/Battery lamps
Built-in type
–10°C to +50°C (14°F to 122°F) (except battery)
30 % to 85 %RH
Dark gray
ø48 x 244 mm (ø1.89" x 9.61")
340 g (0.75 lb) (with battery)
Storage case ........................................................ 1
Rolling stopper ..................................................... 1