Diagnostic (Reset alarms)
[ *
RESET ALARMS ]
à
à
à
PLANT
DIAGNOSTIC
To delete the alarm chronology, select ON, using the
arrow. The press
ENTER
to make the change.
Diagnostic (Enable diagnostics mode)
[ *
ENABLE DIAGNOSTICS MODE ]
à
à
à
PLANT
DIAGNOSTIC
To switch the chronothermostat to Test mode, select ON,
using the
Up
arrow. The press
Enabling this function, battery consumption increases.
Diagnostics (Identify actuator)
[ *
IDENTIFY ACTUATOR ]
à
à
à
PLANT
DIAGNOSTICS
To identify a particular actuator, select an identification
number using the Up/down. Then press
the identification phase.
This operation may take a minute. Immediately after be-
ing identified the actuator corresponding to the number
selected will cause the Led indicator to flash.
Diagnostics (Identify zone)
[ *
IDENTIFY ZONE ]
à
à
à
PLANT
DIAGNOSTICS
The same procedure as the identification of an actuator,
it involves all devices in the selected zone (See 'Identify
Actuator').
User name
[ *
USER NAME ]
à
PLANT
à
To identify the device controlled by the chronothermostat
and its associated zones, assign a name to this field. See
'Zone names' on pg. 8 for instructions.
Area settings
[ *
AREA SETTINGS ]
à
à
PLANT
If the conditions of transmission with the actuators are
favorable, it is possible to modify the capacity of the ra-
dio signal. To do this, access the Area settings section
and select
Normal area
with the
Number of managed zones
[ *
NUMBER OF MANAGED ZONES ]
à
à
PLANT
After providing further confirmation, the total number of
associated zones can be changed, and can include up to
a maximum of 8 zones.
NOTE: the bypassed zones can later be restored.
Reset the advanced settings
[ *
ADVANCED SETTINGS RESET ]
à
à
PLANT
Enable this function when you intend to delete the
changes that have been made to the advanced settings.
A warning is prompted before you can proceed. Select
ON, using the
Up
arrow. Then press
change.
[19]
Up
ENTER
to make the change.
ENTER
to start
Up/down
arrows.
ENTER
to make the
For help see 'NAVIGATION MAP' on pg. 22
Total device reset
[ *
TOTAL DEVICE RESET ]
à
à
PLANT
Through this option, it is possible to restore the chrono-
thermostat to its initial state, according to the factory
settings. After providing further confirmation, restore the
time bands and all the parameters. Select ON, using the
Up
arrow. Then press
ENTER
way, all the data relative to the associated actuators and
all the options edited after installation will be cancelled.
To reuse the actuators you must carry out the associa-
tion operations, as indicated in the following chapter.
ASSOCIATION OF AN ACTUATOR WITH THE CHRONO-
THERMOSTAT
Each actuator requires a basic procedure for establishing
a connection with the chronothermostat which is defined
as 'Association'. When the actuator is not associated, it
responds to each touch of the front selector with the
Signal A*
(See 'Signals' in the following chapter). To start
transmission to the chronothermostat, use the controls
on the chronthermostat itself as follows. To begin, press
the
MENU
key and select
Associations
arrows. Then press ENTER.
Select the desired zone from the menu list using the
down
arrows and then press
names of the zones, see 'Zone Names' on pg. 8). Now
you can associate an actuator to the zone selected. En-
able the search function, maintaining the actuator's front
selector in the
SELECT
position until Leds 2 and 5 light up,
which happens after 10 seconds. Release the button after
this signal. The search remains active for 5 minutes.
LED INDICATOR ILLUMINATION WHEN
FRONT SELECTOR IS PRESSED
Press
sec
duration
à
Led 1
µ
Led 2
µ
Led 3
µ
Led 4
µ
Led 5
µ
Led 6
µ
(µ = Led on)
Signal C*
of the actuator defines the success of the
TECHNICAL SECTION
to make the change. In this
using the
Up/down
Up/
ENTER
(to customize the
5
10
20
30
sec
sec
sec
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ