To 12 VAC
Transformer
10.2 cm (4 in)
Ridgid
2.54 cm (1 in)
Conduit
Figure 2, Gunite Light Installation Diagram
Installing GloBrite
To install the GloBrite
1.
Drill or punch a 5 cm (2 in) hole in the desired location for the GloBrite light
niche.
2.
Place the sealing gasket on the niche as shown below.
3.
Insert the niche through the 5 cm (2 in) hole in the pool wall.
4.
Install the PVC washer to the back of the niche.
5.
Install the plastic nut onto the back of the niche. Hand tighten the nut to
secure the niche in place.
6.
Glue the 2.5 cm (1 in) conduit into back of niche.
2.54 cm (1 in) Conduit
GloBrite White Light Niche (Fiberglass pool) Installation Diagram
1.22 m (48 in) minimum
Niche Sleeve: 5.08 cm (2 in) PVC Pipe
35.1 cm (15 in)
For Gunite Niche Only
Light Niche in a Fiberglass Pool
white light niche in a fiberglass pool:
Niche
(20.3 cm (8 in)
USA: 10.2 cm
(4 in) to top of
Niche Sleeve
(cut flush to wall
before plastering)
Plaster Finish
Pool wall
Nut
PVC washer
GLOBRITE™ White LED Light Installation and User's Guide
Canada: 600 mm max.
to centerline of the Lens
lens
Color Ring and Gunite Cover
Sealing gasket