The machine collects insufficient
moisture in relation to the
ambient conditions.
The machine collects insufficient
moisture in relation to the
ambient conditions.
The machine collects insufficient
moisture in relation to the
ambient conditions.
The machine collects insufficient
moisture in relation to the
ambient conditions.
The machine collects insufficient
moisture in relation to the
ambient conditions.
The machine collects insufficient
moisture in relation to the
ambient conditions.
During operation without tray the
drain pump does not drain the
condensates.
During operation with tray the
drain pump does not drain the
condensates.
During operation with tray the
drain pump does not drain the
condensates.
During operation with tray the
drain pump does not drain the
condensates.
Liquid spills out.
Liquid spills out.
Liquid spills out.
Liquid spills out.
Other
Make sure the setting of the humidistat is sufficient for the
desired conditions.
Make sure relative humidity of the room is within operation
range.
Make sure all air passages, both intake and delivery, are free
from obstruction. If they are obstructed, clean them according
to the instructions in this manual.
Make sure the condenser lamellar pack is not obstructed by
excessive dirt. If it is, clean according to the instructions in
this manual.
Make sure the defrost cycle completely removes the ice from
the evaporator coil. If it does not, you must check the
defrosting components and their operation.
Check the surface temperature of the coil during operation to
make sure it is quite below the ambient temperature. If it is
not, check the cooling system.
Make sure the slope between the machine and the drainage
point is sufficient to allow drainage by force of gravity. If it is
not, raise the machine level.
Make sure the slope between machine and the drainage point
is no steeper than the slope recommended in this manual. If it
is, you must lower the drainage point or raise the machine.
Make sure the pump suction device is positioned in the tray
and that the filter is not clogged.
Make sure the electrical device that controls the pump is in
good condition.
Make sure the machine is in the vertical position.
Make sure the tray is positioned properly.
In cases of operation without a tray, make sure the drain tube
is securely fastened to the tube holder.
In cases of operation with a tray, make sure the drain tube is
securely fastened to the tube holder.
Contact a specialized authorized technician.
GB 14
Ordinary
Ordinary
Ordinary
Extraordinary
Extraordinary
Extraordinary
Ordinary
Ordinary
Ordinary
Extraordinary
Ordinary
Ordinary
Ordinary
Ordinary
Extraordinary