To improve equipment weight distribution, it will be placed on a bench following design
criteria.
Always place the equipment upright and levelled.
This equipment is designed to work indoors if equipped with a centrifugal fan or outdoors
if equipped with an axial fan.
Enough free space should be left around equipment for its proper operation and possible
maintenance operations. In addition it will be verified that air in and outlets are not obstructed.
Outdoors placement should not be done under roofs too inclined to avoid excessive water
drains from falling.
It is not recommended to place the equipment 1.5 meters above the pool, or 3 meters
bellow.
During equipment operation, water condensation may appear, produced by the evaporator.
For this reason the equipment have an outlet tube on side cover which should always be free of any
obstruction and connected to drain.
To avoid any corrosive process in condenser battery, the equipment will not be placed in
acid or alkaline environments.

13. ELECTRICAL CONNECTIONS

The electrical installation should be done by qualified professionals with the following
components:
• Differential circuit breaker.
• Circuit breakers or thermal-magnetic circuit breakers.
Pictures below show how connections should be made:
Always check that the supply voltage corresponds with the voltage which appears on the technical
characteristics nameplate of the equipment.
All wiring should comply with local and national electric codes and should not be prone to
overheating and subsequent voltage failures. As a guide, you can use the table shown below for
lengths of less than 5 meters. All local and national codes should be respected all times.