CONTROL CARD FOR ONE OR TWO 230 Vac SINGLE-PHASE MOTORS FOR OVERHEAD
DOORS
•
MICROPROCESSOR-CONTROLLED LOGIC
•
INPUT STATUS LED'S
•
LINE INPUT FUSE
•
BUILT-IN FLASHING LIGHT CIRCUIT
•
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
•
INCORPORATED ELECTRONIC TORQUE LIMITER
•
ELECTRONIC PEAK LOAD CONTROL
•
CONTROL OF THE SENSITIVE EDGE according to the EN 954-1 standard
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts.
-
do not re-use old pre-existing cables.
INSTALLATION
Before proceeding, make sure the mechanical components work correctly. Also check that the
gear motor assembly has been installed according to the instructions.
THE EQUIPMENT MUST BE INSTALLED "EXPERTLY" BY QUALIFIED PERSONNEL AS REQUIRED
BY LAW.
NB : it is compulsory to earth the system and to observe the safety regulations that are in force in
each country.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE PROPER
WORKING ORDER OF THE EQUIPMENT AND CREATE HAZARDOUS SITUATIONS FOR
PEOPLE. FOR THIS REASON THE "MANUFACTURER" DECLINES ALL RESPONSIBILITY FOR
ANY MALFUNCTIONING AND DAMAGES THUS RESULTING.
TESTING
When you have completed the connection:
All the green LS LEDs must be on (each of them corresponds to a Normally Closed input). The go
off only when the controls to which they are associated are operated.
The red DL5 LS LED must be off (corresponding to the Normally Open OPEN/CLOSE input). It
only comes on when it is activated by the control to which it is associated.
The red DL7 LS LED must be on (giving indications during the programming of the radio control
device).
Power input to board
Max motors nominal power
Fast acting fuse for protection of input power supply 230 Vac (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
Fast acting fuse for protection of auxiliary circuits 24 V dc (F2 - 5x20)
Working temperature
DIAGNOSTICS LED
DL1
SENSITIVE EDGE green LED signal
DL2
OPEN LIMIT SWITCH green LED signal
DL3
CLOSE LIMIT SWITCH green LED signal
DL4
External input STOP green LED signal (terminal 17)
DL5
OPEN/CLOSE button red LED signal
DL6
PRESSURE-SENSITIVE EDGE green LED signal
DL7
RECEIVER PROGRAMMING INFORMATION and ERRORS red LED signal
DL8
Integrated push button panel Stop green LED signal
12
K892M
English
230 Vac - 50 Hz
400 W
F 500 mA
230 Vac
24 Vac
F 6,3 A
-20°C ÷ +70°C