Attila PRF 960 Instrucciones De Uso página 141

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ADJUSTMENT OF THE OVEN
BURNER MINIMUM
This needs to be done only for the oven
burner by acting on the thermostat in the
following way:
– turn on the burner by setting the ther-
mostat knob on position max.
– remove the knob and unscrew the by-
pass screw (fig. 8.9) about three times
by passing a small flat screwdriver (Ø
3 mm blade, 100 mm length) through
the panel opening
– re-mount the knob and let the oven
heat up for about 10 minutes, then
bring the knob to position 1 (minimum)
to operate the thermostat by-pass
– after having removed the knob again
and being very careful not to turn the
tap rod, slowly screw the by-pass
screws "G" (fig. 8.9) until you obtain a
flame of 3-4 mm in height.
N.B. For G30/G31 the by-pass screw
must be fixed thoroughly.
G
Fig. 8.9
Flame correct
Flame faulty in
primary air
Flame with excess
primary air
IMPORTANT
All intervention regarding installa-
tion maintenance of the appliance
must be fulfilled with original facto-
ry parts.
The manufacturer declines any lia-
bility resulting from the non-com-
pliance of this obligation.
LUBRICATION OF THE GAS TAPS
– In case of difficulty in the gas taps
operation, call Service.
141
Tabla de contenido
loading

Productos relacionados para Attila PRF 960

Tabla de contenido