Safety Notes
Gloves	should	be	worn	during	installation	to	prevent	
crushing	and	cutting	injuries.
The	shower	system	may	only	be	used	for	bathing,	
hygienic	and	body	cleansing	purposes.
Children	as	well	as	adults	with	physical,	mental	and/
or	sensoric	impairments	must	not	use	this	shower	
system	without	proper	supervision.	Persons	under	
the	influence	of	alcohol	or	drugs	are	prohibited	from	
using	this	shower	system.
The	hot	and	cold	supplies	must	be	of	equal	pres-
sures.	
Installation Instructions
The	fitting	must	be	installed,	flushed	and	tested	after	the	
valid	norms!	
Thermostatic mixer in conjunction with
combination boilers
•
If	fitting	a	hand	shower	remove	the	water	limiter	from	
the	shower.
•
If	the	continuous	water	heater	causes	any	problems,	
or	you	have	different	water	pressures	you	must	
install	a	water	limiter	to	the	cold	supply,	(ordered	
separately,article	number	97510000).
Thermostatic	mixer	Shower:	When	using	the	Ecostat	
•
with	combination	boilers,	the	Ecostop	safety	set	
(98916000)	has	to	be	removed.	
Technical Data
Operating	pressure:	
Recommended	operating	pressure:	
Test	pressure:	
(1	MPa	=	10	bar	=	147	PSI)
Hot	water	temperature:	
Recommended	hot	water	temp.:	
anti-pollution	function
6
English
Symbol description
max.	1	MPa
0,1	–	0,5MPa
1,6MPa
max.	80°C
65°C
Assembly see page 60
Do	not	use	silicone	containing	acetic	acid!
Cleaning recommendation
see	enclosed	brochure.
Test certificate (see	page	61)
Safety Function (see	page	62)
The	desired	maximum	temperature	for	exam-
ple	max.	42º	C	can	be	pre-set	thanks	to	the	
safety	function.
Adjustment (see	page	63)
After	the	installation,	the	output	tempera-
ture	of	the	thermostat	must	be	checked.	A	
correction	is	necessary	if	the	temperature	
measured	at	the	output	differs	from	the	
temperature	set	on	the	thermostat.
ECOSTOP (see	page	64)
Maintenance (see	page	65)
•
To	guarantee	the	smooth	running	of	the	
thermostat,	it	is	necessary	from	time	to	
time	to	turn	the	thermostat	from	total	hot	
to	total	cold.	
•
The	mixer	is	equipped	with	non	return	
valves.	The	non	return	valves	must	be	
checked	regularly	according	to	DIN	EN	
1717	in	accordance	with	national	or	re-
gional	regulations	(at	least	once	a	year).