Tabla De Contenido; Introduction To The Instructions And Warnings; Product Description - Roger Technology R90/F4ES Instrucciones Y Advertencias Para El Instalador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
EN
TABLE OF CONTENTS
1
Introduction to the instructions and
warnings
This manual is intended only for qualified technical
installation personnel.
No information contained herein may be considered of
interest to the end user.
This manual refers to synchronizable photocells R90/F4ES
and G90/F4ES and should not be used for other products.
WARNING
Read the instructions carefully before installing.
The installation must be performed only by qualified
technical personnel in accordance with relevant legislation.
Perform connections with cables that are adequate to the
current and voltage requirements and comply with the
product specifications.
In order not to affect their proper functioning, the
photocells must be properly aligned without using
reflections and must not interfere with other photocells,
whether they be of the same or of different types. It is
possible in fact, to encounter interference between pairs
of not-synchronized photocells, including more than four
pairs of synchronized photocells or other devices that emit
infrared light. Take all the necessary precautions in order
to eliminate this problem.
To understand the issues related to reflection and
interference between unsynchronized pairs see figure 2.
CAUTION: If the installation requires a distance between TX
and RX of less than 2.5 meters, then the TX and RX lenses
must be removed: otherwise their proper functioning
cannot be guaranteed. Whatever the case, the minimum
distance allowed is 80 centimetres.
WARNING: It is essential to change the configuration of the
jumpers when in the absence of voltage since they are only
read upon ignition and to prevent damage to components.
ATTENTION: in case of AC power supply, connect all TX and
RX with the same polarity.
6
Page
2

Product description

6
6
The synchronized photocells versions R90/F4ES and G90/
7
F4ES are presence detectors that use infrared technology,
7
which allow for the detection of obstacles in the optical
7
axis between the transmitter and receiver photocells, they
7
can be used for automatic entrances, for courtesy services
8
and monitoring passageways.
8
8
Synchronization allows you to connect up to 4 pairs of
8
photocells without worrying that they may interfere with
9
each other. Synchronization is accomplished through
9
an additional wire that connects all the photocells
9
transmitters and receivers.
26
Synchronization is achieved with a photocell TX, called
MASTER, and is transmitted to the receiver coupled to it
and to all the other pairs of photocells available (called
SLAVE).
For these instructions, the transmitter photocell is called
TX photocell, the receiver photocell is called the RX
photocell, while one or more pairs of photocells (always
composed of an RX and a TX photocell) will be referred to
as photocells.
These photocells are intended for installation on mounting
surfaces that are flat and parallel to each other, which
enable proper centring between the TX and the RX
photocells.
Available versions:
• R90/F4ES
• G90/F4ES
• G90/F4ES/TRIX/TX
designed only for installation on the column TRIX series.
and
G90/F4ES/TRIX/RX
are
Tabla de contenido
loading

Este manual también es adecuado para:

G90/f4es

Tabla de contenido