4. STORAGE AND MAINTENANCE

IMPORTANT Routine and accurate maintenance is essen-
tial in maintaining original machine safety and performance
levels.
Store the machine in a dry place.
Disconnect the machine from the mains power supply
before starting any cleaning, inspection or maintenance
activities.
IMPORTANT Only the work described in this manual may be
performed by the user, all other work must be performed by
an authorized service centre.
1)
  W ear sturdy work gloves before cleaning, maintaining 
or adjusting the machine.
2)
After each use, remove the collection box and clean 
the remaining debris in the discharge chute.
3)
Always make sure the air vents are free of debris.
4)
Do not spray water onto and avoid wetting the motor 
and electrical components. Do not use harsh liquids to 
clean plastic parts.
5)
Do not ever try to perform complicated repair work; 
work that is not described in this manual must be 
performed by an authorized service centre. Any work, 
except that which is described in this manual, which 
is not performed by an authorized service centre will 
void the Warranty and will exclude the manufacturer 
from liability.

5. ENVIRONMENTAL PROTECTION

Environmental  protection  should  be  a  priority  of  considera-
ble  importance  when  using  the  machine,  for  the  benefit  of 
both society  and the environment in which we live.
–    A void causing any disturbance to the surrounding area.
–  Scrupulously comply with local regulations for the disposal 
of waste materials after working.
–  Scrupulously  comply  with  local  regulations  for  the  dis-
posal of packaging, deteriorated parts or any elements with 
a  strong  environmental  impact;  this  waste  must  not  be  dis-
posed of as normal waste, but must be separated and taken 
to  specified  waste  disposal  centres  where  the  material  will 
be recycled.
–    W hen decommissioning, do not abandon the machine in 
the environment, but hand it over to a disposal centre, in 
accordance with the local regulations in force.
6. DIAGNOSTICS
Source of problem
1. The machine does not work
Electric current does not reach
the machine
2. Machine start up initiates the automatic general power supply
The capacity (in amps) of  the 
line that feeds the mains power 
socket  is insufficient
Other electrical appliances are
working
3. The machine stops during work
The protection device triggers
4. The machine stops frequently during work or it does not
operate in a regular manner
Demanding working conditions
Clog in the feeding hopper
The cutting blade is dull
The grass-catcher is clogged
5. Poor and unsatisfactory performance levels
The cutting blade is dull
For any doubts or problems, please do not hesitate to con-
tact your nearest Customer Service Centre or Your Dealer.
10
What to do when ...
Corrective action
Check the electrical connection
switch
Connect the machine to a mains 
power socket  with enough am-
perage to power the line
Do not connect other equipment 
to the same power line at the 
same time 
Wait at least 5 minutes before 
restarting the motor
Chip softer material
- Empty the bag 
- Remove the feeding hopper 
(see paragraph 3.5)
Take the machine to the author-
ized service centre for replace-
ment of the blade
Empty the grass-catcher regularly 
before it fills completely
Take the machine to the author-
ized service centre for replace-
ment of the blade