This heater is for wall mounting only. Do not attempt to use it
free standing.
You need to follow the below requirements when you install
your heater:
THIS PRODUCT IS SUITABLE FOR BATHROOMS ZONE
2 AND OUTSIDE ZONE;
- Means for disconnection having a contact separation in all
poles must be incorporated in the fixed wiring in accordance
with the wiring rules.
- Warning: you need to connect the two conductors of the
supply cable to a connection block in respecting the
polarities as following:
IMPORTANT: The wires in the mains lead are coloured in
accordance with the following code:
Blue – Neutral
Brown – Live
The blue wire must be connected to the terminal marked with
an N or coloured black.
The brown wire must be connected to the terminal marked
with an L or coloured red.
WARNING: Never connect live or neutral wires to the earth
terminal.
This product is double insulated and must not be
earthed. If there are any incoming earth cables, they must be
joined together using a suitable connector (not supplied) and
well insulated with good quality insulation tape. This is to
ensure earth continuity throughout your property.
All fittings must be installed by a competent person in
accordance with the current IET Wiring Regulations
(BS7671). If in doubt, consult a qualified electrician.
Before you start