Rowenta MINI SPACE RO18 Series Manual Del Usuario página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

• Open the lid (8) of your vacuum cleaner fig. 13.
EN
• Pull out the HEPA* filter cassette (13) - fig. 31-32.
• Tap the HEPA* filter cassette (13) on the top of a bin - fig. 33.
• Then pass it through clear water, fig 34 and let it dry for at least 24 hours- fig 35.
• Ensure that the HEPA* filter cassette (13) is fully dry before re-inserting it in the machine.
• Place the pins in the notches- fig. 36.
• Adjust the HEPA* filter cassette (13) in its compartment - fig. 37.
• Make sure the HEPA* filter cassette (13) is properly positioned before closing the lid. (8).
CHANGING THE HEPA FILTER CASSETTE * (Ref. RS-RT9926)
• Open the lid (8) of your vacuum cleaner fig. 13..
• Pull out the HEPA* filter cassette (13) - fig. 38-39.
• Put the cassette in the bin- fig.40.
• Place the pins of the new HEPA* filter cassette in the notches - fig 41.
• Adjust the new HEPA* filter cassette (13) in its compartment - fig. 42.
• Make sure the HEPA* filter cassette (13) is properly positioned before closing the lid. (8).
CLEANING THE VACUUM CLEANER
• Wipe the body of the appliance and the accessories with a soft damp cloth, then dry.
• Wipe the lid with a dry cloth -fig. 43.
• Do not use aggressive or abrasive detergents.
6. TROUBLESHOOTING
Important : As soon as your vacuum cleaner begins to work less well than usual, switch it off by pressing
on the On/off pedal, before doing any checking.
YOUR VACUUM CLEANER DOES NOT START
• The appliance is not connected to a power supply . Check that the appliance is correctly connected.
IF YOUR VACUUM CLEANER HAS NO SUCTION
• An accessory or the flexible tube is blocked : unblock the accessory or the flexible tube.
• The lid is not properly closed : Check the positioning of the bag and close the lid again.
IF YOUR VACUUM CLEANER LOSES SUCTION, MAKES NOISE, WHISTLES
• An accessory or the flexible tube is partially blocked. Unblock the accessory or the flexible tube.
• The bag is full, or saturated with fine dust : replace the paper bag (16a), or empty the textile bag* (16b).
• The "bag full" indicator is red : the filtration system is saturated.
- HEPA* Cassette : change the HEPA* cassette (13) and replace it in position, or wash the HEPA* cassette
(13) according to the procedure.
- Micro filter* : take out the micro filter* and replace it with a new one (ref. ZR0039 01).
• The mechanical power control is open : close the mechanical power control.
IF THE "BAG FULL" INDICATOR STAYS RED
• The bag is full. Replace the paper bag, (16a) or empty the textile bag* (16b).
IF THE LID DOES NOT CLOSE (filter presence detector 13bis activated)
• Check that you have installed a HEPA* filter cassette (13) or motor protection grill (11) and check that it
is correctly positioned.
IF THE SUCTION NOZZLE IS DIFFICULT TO MOVE
• Open the regulator to turn down the power.
IF THE CABLE DOES NOT COMPLETELY RETRACT
• The cable is held back by something outside its entry point : straighten out the cable and press on the
cable return pedal.
* According to model: this is either equipment specific to certain models or available as an optional accessory
Tabla de contenido
loading

Tabla de contenido