Speck pumpen BADU Resort Instrucciones De Montaje página 50

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7.2
CAUTION
When the pump is shut off by the thermal security in the windings or by the
motor overload switch, the power supply must be cut off and one must check
whether the pump can still turn unobstructed. To do so try rotating the motor
shaft at the fan side with a screwdriver or other tool that will do. If rotating the
motor shaft requires considerable force, the pump must be checked by an
expert. If it rotates easily, remove your tool and restore the power supply. As
soon as the motor has cooled down, the thermal security in the windings will re-
activate itself, respectively the motor overload switch can be pressed down.
This only may happen one more time. If the pump still shuts off because of the
thermal security in the windings or because of the motor overload switch the
cause of the malfunction is to be determined by an expert (e.g. blocking of the
pump due to impurities or sand swept up while vacuuming the bottom of a
pool). Check current supply and fuses.
7.3
CAUTION
If the pump seizes, it has to be cleaned. Repeated starting of a blocked pump
may cause damage to the motor. In that case any guarantee is voided!
7.4
CAUTION
The leakage pipe on the underside between pump housing and motor must
never be clogged or sealed; otherwise the water in it will rise and the motor will
be damaged! Please make sure that leakage cannot cause consequential da-
mages! If necessary provide a suitable drip pan.
7.5 Removal of salt crystals from the BADU Resort AK – with plastic lantern
Check the plastic lantern regularly for salt crystal deposits (due to salt water).
Remove any crystals that may have formed on the lantern.
Make sure all parts are disconnected from the mains before doing any
maintenance work.
48
Tabla de contenido
loading

Este manual también es adecuado para:

Badu resort ak

Tabla de contenido