The electrical installation must be carried out by a qualified professional (an electrician, for
example) according to the applicable laws and regulations of the target country.
•
The dehumidifier circuit must be linked to a safety earth circuit levelled to the terminal block.
•
The cables must be correctly installed so that they do not cause interferences (items in the
lead boards).
•
The unit may be connected to an earthed 230/2/50Hz general-purpose power supply.
•
Next table shows some indicative sections, which must be verified and adapted according to
the installation needs and conditions.
•
All wiring should comply with local and national electric codes and should not be prone to
overheating and subsequent voltage failures. As a guide, you can use the general power
supply table for lengths of less than 25 metres.
•
The acceptable tolerance to voltage fluctuation is +/- 10% during operation.
4.2.1 Electrical data
Voltage. (V)
2
Section (mm
)
Nº of wires.
Compressor. (A.)
Fan. (A.)
TOTAL.
Voltage. (V)
2
Section (mm
)
Nº of wires.
Compressor. (A.)
Fan. (A.)
Electric Battery. (A.)
TOTAL.
Voltage. (V)
2
Section (mm
)
Nº of wires.
Compressor. (A.)
Fan. (A.)
TOTAL.
© ASTRALPOOL 2008. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
6,01
7,04
1,1
1,1
7,1
8,1
Amp.
220
4
2P+Ground
6,01
7,04
1,1
1,1
18,2
18,2
25,1 Amp.
26,1 Amp.
6,01
7,04
1,1
1,1
7,1
8,1
Amp.
Table 4: Electrical data.
220
4
2P+Ground
9,1
1,1
10,1
Amp.
Amp.
2P+ Ground
9,10
1,1
22,7
33,2 Amp.
220
4
2P+Ground
9,1
1,1
10,1
Amp.
Amp.
ENGLISH
10,4
1,1
11,5
Amp.
220
6
10,40
1,1
22,7
34,5 Amp.
10,4
1,1
11,5
Amp.
Page 46 of 69