Page 8
3.4 Nature
Fusion Installation
2
Nature
2
Fusion Inground
Flow
Figure 3.
Nature
2
Fusion Installation Example
1.
Make sure the pool pump is turned off.
2.
Remove the temporary cap on the cartridge side of the vessel, and install the Nature
in the box.
3.
Locate a suitable section of pipe to install the vessel, approximately 17
installation requirements outlined in Section 3.2.
" (35 cm) section of the 2" (or 5 cm) pipe to insert the vessel (see Figure 4).
4.
Cut out a 13
/
7
8
5.
Connect the outlet from the fi lter or heater to the vessel inlet port with the appropriate Schedule 40 PVC pipe;
secure the connection with a pipe glue that is compatible with PVC.
NOTE Reducer bushings can be used to accommodate 1.5" (3.8 cm) plumbing with no effect on the
operation of the Nature
6.
Connect the vessel outlet port to the pool return line with the same type of PVC pipe and secure the connection
with pipe glue. Allow suffi cient time for the glue to dry.
Flow
Outlet
Figure 4.
Pipe Cutout
Nature
2®
Fusion Inground Installation and Operation Manual
Heater
Flow
Fusion.
2
A
Flow
Plug
Pool
Return
"
(43 cm) long, that conforms to the
Universal Unions and Nuts
for Inlet and Oulet ports
Inlet
with the full unions.
NOTE Total length of the Nature
with the full unions is 16 " (42 cm).
Pump
Filter
Pool
Intake
Spa
Intake
Spa
Return
2
start-up cartridge included
A
Fusion vessel
2