Hamilton Beach PrimaVac HVC406 Manual De Uso página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Changing Preset Vacuum and Sealing Times
This unit comes with 10 preset programs that can be customized with user preferences depending on most
frequent usage.
Factory Default for All 10 Programs (P0 to P9)
Vacuum time: 30 seconds. Can be adjusted from 10 to 60 seconds.
Gas flush: 5 seconds. Can be adjusted from 0.0 to 30 seconds.
Seal time: 2 seconds. Can be adjusted from 0.0 to 3.0 seconds.
Soft air: 2 seconds. Can be adjusted from 2.0 to 30 seconds.
Programming and Storing
NOTE: P0 cannot be changed.
1. In standby mode, display will show "ooo" and PROGRAM DISPLAY will show current program number.
2. Press PROG 1-10
button to scroll through programs to find desired program number.
3. Press REPROG
button. Program number will flash until desired program is set. VACUUM INDICATOR
will illuminate to show selected vacuum time.
4. Press +/STOP VAC
5. Press FUNCTION SELECT
6. Press +/STOP VAC
7. Press FUNCTION SELECT
8. Press +/STOP VAC
9. Press FUNCTION SELECT
time.
10. Press +/STOP VAC
11. Press REPROG
to save parameters.
These are the programmable ranges for each of the four steps:
Using Inert Gas
NOTE: Gas tank pressure gauge should not exceed 14.5 psi.
1. Connect inert gas tank to gas nozzle on left side of machine.
2. Program should be set from following above directions.
3. Minor adjustments can be made by adjusting pressure of inert gas from tank. DO NOT EXCEED 14.5 psi.
4. Place pouch opening around gas flush ports and straight across seal bar.
5. Close lid.
NOTE: If no gas is needed and tank is connected to chamber vacuum sealer, then gas time should be
set at "0.0".
or –/STOP
to change vacuum time.
. GAS INDICATOR
or –/STOP
to change GAS time.
. SEAL INDICATOR
or –/STOP
to change SEAL time.
. SOFTAIR INDICATOR
or –/STOP
to change SOFTAIR time.
Name
Vacuuming Time
Gas
Sealing Time
Soft Air Time
will illuminate to show selected GAS time.
will illuminate to show selected SEAL time.
will illuminate to show selected SOFTAIR
Time
10–60 seconds
0.0–30.0 seconds
0.0–3.0 seconds
2.0–30.0 seconds
7
Tabla de contenido
loading

Tabla de contenido