Risk of destroying the motor.
The device requires a voltage of 24V ═ (DC). Higher voltage may destroy the motor.
-
-
The lock must be powered with a voltage of 24V ═ (DC). The power supply cable has three wires with red copper
conductor, sheathing and insulating core in PVC, where:
"1" connected to the + (positive) CLOSE;
R
ED
"2" connected to the + (positive) OPEN;
B
LACK
"3" is the communication signal with the chain actuator.
G
REEN
The electromechanical lock must be powered using a station with emergency batteries or an approved class II power
supply unit (double safety insulation) with an output voltage of 24V═ (-15% ÷ +25%, i.e., min. 20.4V, max. 30V).
7. SETTING THE DIP-SWITCHES – Selecting the stroke and setting the
operating mode.
The programming dip-switches are located under the cap on the side of the hook. The selection is made
using a small screwdriver or tweezers.
This dip-switch is used to set two different strokes of the hook: 18 or 36 mm. The
selection is determined by the type of application. The hook must completely free the
pawl of the sliding accessory by at least 3-5 mm.
Dip-switch n. 1
The dip-switch:
This is the dip-switch that allows the user to select the operating mode: "with actuator"
or " free" (without actuator).
This dip-switch:
Dip-switch n. 2
Never connect a 24V unit to a 230V voltage! Life-threatening!
Low-voltage line and power line must be separate.
-
when placed in the ON position, sets the stroke to 18 mm:
-
when placed in the OFF position, sets the stroke to 36 mm.
when placed in the OFF position, the
occurs according to the polarity of the power supply between wire Red and wire
Black: wire Red +24V →
This mode is useful during assembly or testing when there's no communication
with the actuators; it's also useful for performing a test in the event of accidental
fault or lack of operation.
when placed in the ON position, it dialogues with the chain actuator according
to the operating logic sequence.
In this case the lock moves only when the chain of the actuator has re-entered
completely.
with actuator
OPEN
, wire Red -24V →
CLOSE
without actuator
23
/
movement of the hook
CLOSE
.
OPEN