Angelo Po 190TP0 Manual De Uso página 61

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

REPLACING OVEN BURNER AIR BUSHING
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Undo the screws (B) and remove the control
panel (A).
3 - Undo the screw (C).
4 - Extract the bushing (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Replace the control panel (A) on completion of
the operation.
DECOMMISSIONING THE APPLIANCE
Important
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work. Never dump non-biodegradable ma-
terials, lubricating oils and non-metallic
A
components (rubber, PVC, resins, etc.)
in the environment. Dispose of them in
accordance with the relevant legal re-
quirements.
- 29 -
B
C
D
IDM-39614603000.tif
IT
GB
DE
FR
ES
English
Tabla de contenido
loading

Este manual también es adecuado para:

191tpg291tpcg

Tabla de contenido