Angelo Po 190TP0 Manual De Uso página 56

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (TOP
BURNERS)
Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
dure has been carried out (see page 22). Be-
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Fully screw the injector.
6 - After making the setting, seal the screw
with paint.
7 - Replace the control panel (B) and the
knobs (A) on completion of the operation.
ADJUSTING GAS VALVE MINIMUM SETTING (OVEN)
IT
Important
This adjustment is only required if the type
GB
of gas to be connected is different from that
used for testing after the conversion proce-
DE
dure has been carried out (see page 22). Be-
FR
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
ES
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Fully screw the injector.
6 - After making the setting, seal the screw with
paint.
7 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
English
fore making this adjustment, check that the
gas supply pressure is the same as the rat-
ed pressure for the type of gas in use (see
table at back of manual).
C
A C
B
fore making this adjustment, check that the
gas supply pressure is the same as the rat-
ed pressure for the type of gas in use (see
table at back of manual).
C
A C
B
- 24 -
D
IDM-39614601800.tif
D
IDM-39614601900.tif
Tabla de contenido
loading

Este manual también es adecuado para:

191tpg291tpcg

Tabla de contenido