To carry out this operation, proceed as follows.
1 - Turn on the tap (A).
2 - Unscrew the cap (B).
3 - Turn the water spout (C) towards the filler con-
nection (D).
4 - Turn on the taps (E) to fill the jacket.
5 - When water starts to flow from the tap (A), turn
off the taps (E) to avoid overfilling.
6 - Turn the tap (A) fully off and screw the cap (B)
back into place.
7 - To empty the jacket, unscrew the cap (F) pro-
vided underneath the appliance.
Caution - warning
Never open the jacket filler cap (B) or the level
checking tap (A) when the appliance is in op-
eration or still hot.
To avoid any health and safety risks (back in-
juries) arising from the handling of the equip-
ment, the basket containing the product must be
removed by two operatives or with the aid of suita-
ble lifting equipment.
IT
IT
To avoid scalding, suitable equipment (gloves,
hooks, etc.) should be used when pulling out the
GB
GB
handles used to lift the basket.
DE
DE
If the safety thermostat is tripped because the water
level in the jacket is too low, the appliance has to be
FR
FR
restored to working conditions as follows.
1 - Check and if necessary top up the water level in
ES
ES
the jacket (see page 10).
2 - Open the hatch (A).
3 - Press the button (B) of the safety thermostat to
restore the Electricity supply.
4 - Close the door (A) when the operation is com-
plete.
Caution - warning
If the safety thermostat is tripped too often,
and the water level in the jacket is correct, call
the after-sales service.
English

FILLING THE JACKET

REMOVING THE BASKET AND USE OF THE HANDLES

RESETTING THE APPLIANCE

C
D
A
F
Customers (Employers) are reminded of their obli-
gation to assess the residual risks to the health and
safety of operatives arising from the use of the ap-
pliance (and its accessories), and to take the appro-
priate preventive measures.
A
- 10 -
B
E
IDM-39616400900.tif
B
IDM-39615500700.tif
Tabla de contenido
loading

Este manual también es adecuado para:

191pi2ea

Tabla de contenido