LED Indicator
Each power sensor has an LED indicator located in the center of the
power meter housing that indicates the status of the power meter under
certain conditions. Use this guide to each function to check critical
functions of your power meter. Note: Gen 1 and Gen 2 Stages Power
meters do not have the LED indicator light on the power meter housing.
Action
Zero Reset
Battery Level
Linking LR
Firmware
Updates
8
LED Indication
Three blue flashes while completing a zero reset.
Green (16-100%), yellow (6-15%), or red (1-5%) flash to
indicate battery level every 10 seconds for first minute
after start up. For LR, left sensor will flash the left, then
right battery level in succession.
Two orange flashes when a left and right sensor are
successfully linked together.
Steady flashing based on battery level while
firmware is being updated via Stages Power app.