IMPORTANT! Any installation operation shall be carried out by a suitably
trained staff, following carefully the information given in this manual.
Check the packaging at the reception of the goods and store only at a dry place. Verify that
the device hasn't been damaged during transport or storage operations. Make sure you re-
ceive all the components. Ask the manufacturer for any possible missing component.
The hose reel has to be wall mounted at a minimum height of the floor of 2.50 m in or-
der to prevent accidents during work operations. Considering the hose reel weight and
dimensions, his movement requires the use of lifter devices.In particular cases it is possible
to mount it on the floor or on other machines as accessory, only if complete with a fixed sup-
port. The hose-guide arms can be fixed in three different positions according to the hose reel
installation (see pictures A-B-C p.41). IMPORTANT! Models with hose 1" for oil only allow
the installation on positions A - B.
Mount the hose reel in fixed position or with revolving stand (optional) on stiff and consistent
walls using 4 dowels of 10 mm diameter. (see drawing p.41)
WARNING! The manufacturer declines any responsibility for injuries to people or da-
mages to things caused by a wrong assembly of the hose reel.
Always connect the hose reel to the line by the couplers and the flexible hose (A) su-
itable for this use, above all in case of high pressure and temperature.
To avoid consequent loss of fluid tighten the fittings using appropriate keys, keep back
the swivel joints to avoid damaging them.
According to the rules, put a ball-tap on the feeding line of the hose reels in order to make
the maintenance operations easier. The said ball-tap can be used as a safety valve for dan-
gerous situations.
9.1
9.2

8 - INSTALLATION

9 - LINK

9.1) Air, Water, Oil, Anti-freeze/Winshield:
When you lock the fitting, hold the swivel joint by the 27
wrench (B) in order not to damage it. Thus it is possible
to avoid consequent losses of fluid from the inside seal
(hose reels for high pressure).
Tighten the swivel joint on the shaft, fit the inlet hose
and the lateral cover.
9.2) Oil (3/4"-1"):
Tighten the swivel joint on the shaft, fit the lateral cover
and tighten the elbow 90° on the swivel joint.
- 12 -