Installation procedure:
Avoid direct exposure to sunrays (caution: over-heating), avoid water and humid environments.
PAY ATTENTION TO POLARITIES AND AVOID SHORT-CIRCUITS; they are destructive and cancel warranty.
Connect the battery cables only after having connected all the others; do not insert a further blocking diode:
you would annul the "light sensor" detection. Put the battery in the chosen place, connecting in the proper
way the cables and reducing the distance from the charge controller more that you can.
We advise the external NTC temperature sensor (optional) in case of big differences in temperature between
controller and batteries. Connect to the proper connector the external NTC temperature sensor and, if
requested by the chosen configuration, connect also either the infrared sensor (PX01) or the switch for
remote habilitation. On starting the LED must effect a green and red lightning to indicate a correct power on.
To test if the installation of the controller has been made in the right way it is necessary to verify that at
sunset the load switches on according to the configuration that has been set by the Switches (ser the
following page). To simulate SUNSET we advise to cover carefully the PV module using a quite thick
cardboard; it could be necessary to cover even the rear side of the PV module. We saw that if you connect to
the controller SPC07-IP2 some kind of PV modules the controller is not able to detect the night. If you are in
such conditions, please contact
Configurations:
In all configurations the following processes are guaranteed:
The regulation of the battery's charge voltage, compensated in temperature, by external or internal NTC.
Load deactivation at reaching Low-Battery threshold (a red ligthning), selectable to 11V (dip switch 6 ON) or 12 V
(dip switch 6 OFF).
System inhibition at reaching Overtemperature threshold (two red ligthnings of the LED).
It is possible to exit from a low battery condition only during daylight.
Switchs
Description
Set the battery type
SW6 on -> LiFePO4 Battery(Voff 14.1V@12V e 28.2@24V (not temperature
ON
compensated)
SW6 off -> Lead Battery (Voff 14.4V@12V e 28.8V@24V temperature
compensated)
1
2 3 4 5 6
Set the disconnection voltage of the load outputs (Low Battery Voltage)
ON
SW5
on
1
2 3 4 5 6
SW5
off
Standard Charger *:
ON
Load A always active.
Load B active only at night.
1
2 3 4 5 6
Twilight complete with complementary outputs *::
ON
Load A active only during the day.
Load B active only at night.
1
2 3 4 5 6
Remote Load *:
Load A controlled by the contact on the Sens input; closed towards gnd load A
ON
active.
Load B always active
1
2 3 4 5 6
Sens
LoadA
LoadB
Western CO. Support
Lead@12
Lead@24
V
V
11.0V
22.0V
12.0V
24.0V
CLOSE
OPEN
OPEN
SPC07-IP2
User manual
Center.
LiFePo4@12.
8V
12.0V
24.0V
12.5V
25.0V
3
EN
Load connection diagram
+LoadA
-LoadA
+LoadB
-LoadB
SPC10-IP
Gnd
Sens
+LoadA
-LoadA
+LoadB
-LoadB
SPC10-IP
REV 1.0 28-04-2020