In the return channel we can also make a fixed equalization of 6dB by the means of jumpers. The different positions of the
jumpers for equalizing or not equalizing the return channel are shown in the following table:
Return channel fixed
equalization (E)
Jumpers position
The equipment is provided with a wall support with wedges and screws included.
The steps to make a correct installation are the followings:
-
Bring down the fastening device. The equipment will be now loosed and it will be possible to separate the support
from the equipment.
-
Fix the support to the wall with the wedged and screws provided.
-
Introduce the equipment again in the wall support once it is installed.
-
Bring up the fastening device to adjust the equipment to the support.
HCA ZM 45-30 / HCA ZM 45-65
1
IN: Input terrestrial signal 5-862 MHz (*)
2
OUTPUT TEST: Output test (-30dB)
3
OUT: Output Terrestrial signal 5-862 MHz (*)
4
AC IN: Power cord ( 230V AC, 50Hz )
(*) Nota: In model HCA ZM 45-30
the
65
margin of input and output frequencies is 85-862MHz and the return path 5-65MHz.
1.4. Accessories and example of installation
Accessories
Cable digital Receiver
Mod. MAX C130
Code 0710015
User's Guide · HCA ZM 45-30 / HCA ZM 45-65
4
the
margin of inputs and output frequencies is 47-862 MHz and the return path 5-30MHz. For model HCA ZM 45-
Cable digital Receiver
Mod. PVR C130 CI HDMI
Cód. 0710104
-6dB
3
1
2
- 3 -
HCA ZM 45-30 / HCA ZM 45-65
0dB
Inductive outlets (Class A)
Mod. AOF 3U
Code. 0960103
Version_en_1.1
FTE maximal