Delete an access code:
After entering the master code and receiving the confirmation through the LED by going on please enter the following sequence:
AA 02 B
AA to indicate
deleting
Programming activation time:
The sequence to program is the following:
31 05 B
Relay
31 corresponds to relay 1
-
32 corresponds to relay 2
-
The activation time values are going from 00 to 99 seconds.
00 corresponds to impulse mode (200ms).
Total deleting of access codes:
The sequence is the following:
35 00 B
All codes will be erased.
Replacement code:
In function mode the replacement code allows to replace an existing code by another code. If the code to be replaced is present in different memory
positions all of them will be replaced by the new code.
How to program a replacement code:
After entering the master code the green LED goes on. Please enter the following sequence:
Code length
36 0 4 2411 B
Memory position
How to use a replacement code:
The sequence to program in function mode is the following:
Time zone
2411 1234 1 5 20045 B
Replacement
Old code
code
This sequence allows to delete the code 1234 and to replace it by the code 20045. In this case the replacement code is 2411.

FUNCTION MODE:

Every time a code is entered and recognised the assigned relay outputs will be activated. All keys realise a blinking and the green LED Hill be on as long
the activation time (1 second in case of bi-stable).
After entering a code with a bi-stable relay output the relay will be as long in the last position as the code is not entered again.
Activating 20 times keys of the keypad without a recognised code induces the keypad to block for 30 seconds.
FOLLOWING UP THE INSTALLATION
For any programmed code write down the numbers following in the M column the activation mode B for bi-stable or I for impulse and the time zone in H.
UM_3200160_ CLAF3AN-A3_Rev05
B to validate
Memory position
B to validate
Time in seconds
Replacement code
B to validate
Time zone
New access code
Code length
new code
B to validate
Page 7/12
Tabla de contenido
loading

Tabla de contenido