Messner M 1200 Instrucciones De Servicio página 5

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
Please read these instructions thoroughly, before using the pump!
GB
Use
Centrifugal pump for submersible usage with resin encapsulated motor.
The pump is suitable for use in water, e.g. for garden ponds, fountains,
terraced fountains, indoor fountains, in fi sh-ponds, for the operation of
fi lter systems, fl owing brooks etc. as well as for circulating and
oxygenating water.
It is not allowed to use the pump in or on the side of swimming
pools!
For all technical data please refer to the type plate.
Safety measures
- Caution! It may only be used in garden ponds and in their protection
area, if the electrical installations have been set up to comply with the
code's requirements. Please contact an electrician.
- Before use: Check whether mains connection and plug are intact.
- Mains voltage and type of current have to correspond to the data on
the type plate.
- The pump has to be connected to a regular safety plug socket
through a residual current device (RCD, 30 mA).
- The connection box should be located in a water-protected area.
It should be at least 2m away from the edge of the pond (see fi g. 1).
- Keep the plug dry!
- Pull out mains plug before starting to work on the pump, fountain
or pond. It is not allowed to run the pump when people are inside
the water (disconnect the pump)!
- Important! When the mains connection or the motor housing are
damaged, the pump cannot be used anymore. It cannot be repaired
since the connection is cast into the motor housing.
- Do never hang up or transport the pump by the cable!
- The pump must be run submerged!
Start-up (see fi g.1)
Important!
Do not let the pump run dry.
This could cause damages to the appliance.
- Immerse the pump completely in your pond. This causes the pump
body to be fi lled with water.
- A water level of approx. 15 cm is required for submersible use in order to
prevent the pump from taking-in air.
- The water temperature should not exceed 35°C.
- Do not let the pump freeze in the wintertime.
- The pump is switched on by putting the plug in the socket.
- To prevent the pump becoming unnecessarily dirty, place it above the
mud in your pond, in a fi rm and horizontal position (on a brick)!
- A range of accessories may be fi tted onto the threaded connection of
the pump.
- Running in conjunction with fountain jets, the pump should be
positioned fi rmly and horizontally (on a brick).
- To prevent the fountain jets becoming clogged, we recommend
you to fi t the enclosed fi lter sponge.
6
Dismantling / Assembly ( see fi g. 2 - 5)
1. Follow the safety measures.
Disconnect the pump!
2. Press together the fi lter cover (1) laterally and take it out of the
pump (8).
3. Pull the fi lter sponge (2) out of the fi lter cover (1).
4. Turn the inlet lid (3) counterclockwise and take it out of the pump (8).
5. Pull the rotor (4) out of the pump (8).
6. The complete rotor (4) can be made to rotate on the axle.
7. The impeller and the magnet, too, may be turned against each other
through a predetermined angle.
8. Clean all components - please use clear water only - so that they
allow to be easily moved. Do not use sharp-edged objects.
9. Proceed as follows in order to reassemble the pump
9.1. Replace complete rotor (4) in the pump (8).
9.2. Insert the inlet lid (3) in the pump (8), holding it in the same position
as when you took it out of it, then turn it clockwise until it stops.
9.3. Insert the fi lter sponge (2) in the fi lter cover (1).
9.4. Insert the front (1) and rear (6) fi lter covers in the pump (8).
To ensure proper functioning, repeat the above procedure frequently,
depending on clogging and working time.
Maintenance
In order to prolong the service life of your pump and to keep it in good
operating condition, it is recommended to carry out maintenance and
cleanup regularly. This can be done by everyone, quickly and easily.
See „Dismantling/Assembly".
Servicing intervals
- In the beginning check performance of your pump every day.
If necessary, clean the fi lters.
- Since servicing intervals (complete cleanup) will vary depending
on pond pollution, repeat the periodic service to your pump in
accordance with the requirements given.
Should you determine that there are damaged or worn parts, do replace
them. See „Spare parts".
Winter / Pump care
Protect your pump from freezing-in!
Take the pump out of your pond in autumn.
Clean the pump completely following the outlined instructions.
During the winter months store the pump in a frost-resistant room.
Spare parts
For ordering spare parts, please indicate the pump type, the de
signation and the Art.-No. as per table below (see also fi g. 5).
Item
Designation
Pump Type
1
Filter cover front
M 1200, M 1600
2
Filter sponge
M 1200, M 1600
3
Lid incl. sealing ring
M 1200, M 1600
4
Rotor complete
M 1200
M 1600
6
Filter cover back
M 1200, M 1600
7
Handle/Stand
M 1200, M 1600
7
Art-No.
168/009063
168/009064
168/009073
168/009068
168/009069
168/009066
168/009072
Tabla de contenido
loading

Este manual también es adecuado para:

M 1600

Tabla de contenido