ENGLISH
Typical application
Fig. 2 ÷ 5;
Fig. 5: A= inlet; B= outlet
NOTE
The appliance's inlet and outlet ports must always be
connected to a suitable duct.
Installation
Fig. 6 ÷14.
NOTE
Use of the supplied brackets is optional.
Function
Figs. 15 ÷20.
The appliance leaves the factory with Minimum (V min )
and Maximum (V max ) speeds set at their nominal
values.
The electronic board fitted to the appliance has two
potentiometers for setting V min and V max (fig.15).
Pre-set speed changes (set by installer)
Any initial adjustment of V min and V max can be
carried out as follows:
- Turn the potentiometers fully anti-clockwise before
connecting the appliance to the mains (fig. 16);
- turn the appliance ON;
- within one hour of turning the appliance ON,
proceed as follows:
* position the external switch at V min ;
* use the V min potentiometer to set V min at the
desired speed; (fig .17)
* position the external switch at V max;
* use the V max potentiometer to set V max at the
desired speed (fig. 18).
* wait about 10 minutes before turning the
appliance off to allow the system time to memorise
the speeds that have been set.
NOTE:
Only adjust the trimmer using non-conductive tools
(e.g. a plastic screwdriver). Any subsequent
adjustments can be made using the same sequence
as above.
Restoring the original speed settings (set by
installer)
- With the appliance turned off, change the original
settings of the dip-switches shown in fig 20. The
new setting will only be temporary and can be any
of those shown in the table for this appliance. (table
A)
- Fully turn the Max and Min speed adjuster anti-
clockwise.
- Turn the appliance on and let it run for at least 10
minutes.
- Turn the appliance off and restore the original dip-
switch settings (table A).
- Turn the Minimum and Maximum speed adjusters
clockwise to the half-way stage.
- Turn the appliance on again.
TAB A
Model
CA 100 ES
CA 125 ES
CA 150 Q ES
CA 150 ES
CA 160 ES
CA 200 ES
Select the pre-set speeds
The user can change between V min and V max using
an external switch (not supplied)
NOTE
Increasing the speed of the motor leads to greater
power consumption and higher noise levels.
NOTE
CA ES series products can be operated in
conjunction with environmental sensors and timers
that switch the products on at a preset speed when
certain thresholds are reached e.g. Relative Humidity
(C HCS), Temperature (C TEMP), Smoke (C Smoke), if
the vicinity detector is activated (C Pir) or while the
Timer is being set (C Timer).
Configuration
ON
OFF
1
2
3
4
ON
OFF
1
2 3
4
ON
OFF
1
2
3
4
ON
OFF
1
2
3
4
ON
OFF
1
2 3
4
ON
OFF
1
2
3
4