Beninca Logica 230 Manual De Instrucciones página 8

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
15
CLOSE
16
Step-by-Step
17-18
24 Vac
19-20
SCA
21-22
COSTA
23-24
Aerial
CM-CM
Capacitor
0-12-12
Secondary
L1-N1-T
Primary
J3
Radio receiver
The courtesy light stays on for about 90s at each operation.
The safety EDGE should be connected only to the special inputs. Two types of EDGE can be used:
If a safety edge is used with 8K2 resistance, the "DAS" jumper should be closed.
If a mechanical safety edge with N.C. contact is used, the "DAS" Jumper should be opened.
If no edge is used, terminals 21-22 should be short-circuited.
1) Power the control unit
2) Manually release the system and completely open the door.
3) Adjust the opening limit switch cam, the SWO LED turns off.
If braking is required in the opening phase, the limit switch triggering should be anticipated.
4) Shut the door completely.
5) Adjust the closing limit switch cam, the SWC LED turns off.
If braking is required in the closing phase, the limit switch triggering should be anticipated.
6) Cut off power supply.
7) Move the door half-way and lock it again.
8) Reset power supply. The STOP, PHOT, SWO and SWC LED's should light up.
9) Give a step-by-step control signal by pressing the appropriate button or using the remote control.
10) The door should move in the opening phase. In the negative, it is sufficient to invert the speed wires (6<>8) of the motor and
the limit switch inputs (SWO<>SWC).
11) Adjust Time and Operating and Motor power logic.
If braking is required, move DIP3 to ON and adjust the braking time of trimmer TSLOW.
WARNING! This adjustment affects the safety level of the automatic system.
Check that the thrust applied onto the wing complies with regulations in force.
On the power supply transformer, a Faston connector (T1) is provided which allows to adjust motor power to 4 different levels. By
positioning the Faston (T1) on 120, the minimum power is obtained, by moving the Faston to 210 the maximum power is obtained.
TCA
It allows to adjust the automatic closure time. Check Dip-Switch N°1= On.
The adjustment varies from 1s minimum to 90s maximum
TSLOW With Dip-Switch 3 On, it adjusts the slowdown cycle time from 1 to 12 secs.
With Dip-Switch 3 Off, it adjusts the work time from 10 to 120 secs. In this case the slowdown option is disabled.
DIP 1
"TCA"
The automatic closure is enabled or disabled
Off: disabled automatic closure
On: enabled automatic closure
DIP 2
"Prelam."
Forewarning flashing light enabled or disabled
Off: disabled forewarning flashing light
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of the motor.
DIP 3
"Rall."
Enables or disables the slowdown cycle.
Off: Slowdown disabled. The TSLOW trimmer adjusts the motor work time from 10 to 120 secs.
Set a work time longer than the duration of an operation.
On: Braking in both opening and closing phases.
N.B.: the braking phase starts when the limit switches are triggered.
8
Input, CLOSE push button (N.O. contact)
Input, step-by-step push button (N.O. contact)
Output, power supply of accessories, 24Vac/1A max.
Free contact, N.O. for open door warning light.
Input, safety edge contact
Resistive edge: Closed "DAS" jumper
Mechanical edge: Open "DAS" jumper
If the safety edge is activated in the opening phase, the gate stops.
In the closing phase, the gate stops and the performs a movement reversion (opens) for
3s.
Connection to the radio receiver card of the aerial (23-screen/24-signal).
Connection, capacitor
Connection, winding of secondary transformer
Connection, winding of primary transformer
Connector for radio receiver.
The RI versions have a built-in radio receiver
REMARKS:
TO ADjUST ThE LIMIT SWITChES
TO ADjUST ThE MOTOR POWER
FUNCTIONS OF ThE TRIMMERS
DIP-SWITCh FUNCTIONS
Tabla de contenido
loading

Este manual también es adecuado para:

Logica 230 riL8542858

Tabla de contenido