Adjusting Gas Control Valve Maximum Setting (12*Cpia) - Angelo Po 10NCP1IA Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ADJUSTING GAS CONTROL VALVE MAXIMUM SETTING (12*CPIA)

Important
Before making this adjustment, check that
the gas supply pressure is the same as the ra-
ted pressure for the type of gas in use (see ta-
ble at back of manual).
Natural gas
Proceed as follows.
Turn off the gas supply tap and switch off the
1)
main electricity supply.
Open the hatch (A).
2)
Undo the screws (B) to remove the guard (C).
3)
Undo the screw of the pressure connection
4)
(E).
Connect the pressure gauge (F) to the pressu-
5)
re test point (E).
Turn the guard (G) anticlockwise and remove
6)
it.
Turn the gas supply tap back on and switch
7)
the main electricity supply back on.
Switch on the appliance.
8)
Fill the well with water and turn the gas sup-
9)
ply tap back on.
Adjust the pressure using the nut (N) to
10)
suit the type of gas being supplied, until the
corresponding value appears on the pressure
gauge (see table at back of manual).
– Turn clockwise to increase the pressure.
– Turn anticlockwise to decrease the pressure.
A
3329640_inst_GB
C
B
B
- 15 -
Switch the appliance off and back on a few
11)
times to check that the setting has been made
correctly.
Switch off the appliance and disconnect the
12)
pressure gauge.
Fully tighten the screw of the pressure
13)
connection (E).
After making the setting, seal the nut (N)
14)
with paint.
Replace the guard (G) and close the hatch
15)
(A).
Bottled gas
Proceed as follows.
Turn off the gas supply tap and switch off the
1)
main electricity supply.
Open the hatch (A).
2)
Undo the screws (B) to remove the guard (C).
3)
Fully tighten the nut (N).
4)
After making the setting, seal the nut (N) with
5)
paint.
E
G
N
ENGLISH
GB
F
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

10tcp1ia12ncp1ia12tcp1ia20ncp2ia20tcp2ia

Tabla de contenido