Components (7: Resistors, 8: Diodes , 9: Capacitors) can only be measured
!
correctly in isolation. It may therefore be necessary to disconnect the components
from the rest of the circuit.
!
To avoid incorrect results the measuring points must be free of dirt, oil, solder lacquer or similar.
!
The components must be off-circuit.

Continuity test

10
1.
Continuity test
A measured value of < 50 ohms is recognised as continuity; this is confirmed by an audible signal.
If „O.L." appears on the display instead of a measured value, either the measuring range has been
exceeded or the measuring circuit is not closed or has been interrupted.
!
The components must be off-circuit.
Contact temperature measurement
11
To measure contact temperature, connect the supplied temperature sensor (K-type) to the device.
Ensure correct polarity.
1.
°C / °F
2.
3.
Ω, continuity
check and diode
check selection
2.
Black
Red
3.
°C/°F
selection
MultiMeter XP
Black
Red