LaserLiner SensoPilot Pro Manual De Instrucciones página 9

Ocultar thumbs Ver también para SensoPilot Pro:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Danger - powerful magnetic fields
Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as
well as electromechanical devices (e.g. magnetic cards, mechanical clocks, precision mechanics, hard disks).
With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and
regulations must be complied with such as BGV B11 §14 „electromagnetic fields" (occupational health
and safety - electromagnetic fields) in the Federal Republic of Germany.
To avoid interference/disruption, always keep the implant or device a safe distance of at least 30 cm
away from the magnet.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents.
Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
Operation of SensoPilot Pro
Power supply
• Before using the SensoPilot, ensure the batteries are fully charged.
• If LEDs 6 / 7 / 8 blink from inside to outside, the batteries need recharging. To do so, remove the cover
of the charger socket (1) and connect the charger. Recharging takes approx. 15 hours.
• Alternatively, the SensoPilot can be operated and be recharged at the same time from the battery of the
construction machine via the 12/24V battery cable. To do this, plug the battery cable into the socket (4).
• When no laser beam is being received, the SensoPilot switches itself off automatically.
Fixing the SensoPilot Pro
The powerful magnets (9) allow the SensoPilot to be fixed directly on the construction machine. Take care
that the contact surfaces are clean and level so as to ensure that the magnets have a firm and reliable hold.
!
The extremely powerful magnets pose a risk of crush injuries.
Putting the SensoPilot into operation
Press the ON / OFF switch once; all the LEDs will flash briefly. The SensoPilot is now ready for operation.
The large oblong receiver fields (5) recognise the laser beam, and the LEDs (6, 7, 8) indicate when the
reference height is reached.
• Upper LEDs blinking: Move the SensoPilot upwards.
• Middle LED (6): The SensoPilot is at reference height.
• Lower LEDs blinking: Move the SensoPilot downwards.
Precision select
Two levels of precision (HIGH and LOW) can be selected. Changeover between the precision levels is done
using the On / OFF switch (10).
• HIGH: The inner LEDs (7) blink 3 times.
• LOW: The outer LEDs (8) blink 3 times.
Switching off the SensoPilot
Press the ON / OFF switch (10) for about 3 seconds.
Rotation laser
For generating a laser reference height, automatic rotation lasers with a high maximum rotation speed are
best.
!
The SensoPilot Pro cannot be used together with line lasers.
SensoPilot Pro
09
EN
Tabla de contenido
loading

Tabla de contenido