Fig. 16
Fig. 17
45
Bevel Stop Adjustment
0
• Loosen the Bevel Lock Handle and tilt the Cutting Head
completely to the left until it rests against the 45
• Use a Set Square to see if the blade is at 45
(avoiding the TCT tips).
• If the saw blade is not in exact alignment adjustment is necessary.
• Return the Cutting Head to its upright position.
• Loosen the locknut on the 45
• Use a Hex Key to adjust the Adjustment Screw in or out as
required. (Fig. 16)
• Tilt the Cutting Head to the 45
alignment with the Set Square.
• Repeat the above steps until the correct angular alignment
is achieved.
• Tighten the Adjustment Screw locknut securely once
alignment is achieved.
CROWN MOULDiNG
The Cutting Head can be tilted (to the LH side only) and locked
at an Bevel angle of 33.9
. The rotary table can be set at 31.6
o
Mitre angle to the left or right hand side. This allows the Rage
machine to be used for cutting 38
To check the 33.9
angle the operator will require a vernier
o
angle gauge (not supplied).
To check the 33.9
Bevel Angle stop:
o
• Deploy the Crown Moulding Pin (see Operations)
• Loosen the Bevel Locking Handle and tilt the Cutting Head to
the 33.9
position.
o
• Slide the vernier angle gauge into position with one arm resting
on the rotary table and the other resting on the tilted blade.
• Read off the angle setting.
if adjustment is required:
• Loosen the locknut on the 33.9
• Use a Hex Key to adjust the Adjustment Screw in or out as
required. (Fig. 17)
• When correct adjustment is achieved, lock the Adjusting
Screw by tightening the locknut.
24
www.evolutionpowertools.com
stop.
0
to the table
0
Bevel Adjustment Screw.
0
setting and recheck for
0
o
Crown Moulding.
o
Adjustment Screw.
o