DETECTING BLOCK PANELS (IM)
This function allows you to detect the existence of panels configured as BLOCK ENTRANCE
within the installation, along with the panel number.
For this, follow these steps indicated in the diagram:
1. DETECTOR
1. DETECTOR
TEST RESULT:
ALL PANELS
No panels have been
detected
TEST RESULT:
NO PANELS
Exit this function and return to the PANEL DETECTION menu
ESC
C ESC
We start from the BLOCK PANEL DETECTION option on
the PANEL DETECTION menu:
BLOCK PANEL
OK
1 2 3
4 5 6
BLOCK: 00
7 8 9
0
ESC
OK
Start testing the 10 possible panel numbers that may exist in
PANELS
the indicated block.
00 00
The two digits to the left indicate the block number being tested,
and the two right ones the panel number.
After having completed the scan, you can view one of these 3 results:
All 10 panels have
been detected
TEST RESULT: ?
TEST RESULT: ?
NO DETECTED
Enter the block number you wish to test.
Values admitted: 00 to 09
Only some panels have been detected.
Choose if you want to view the detected or
undetected ones.
OK
DETECTED
OK
PANEL OK:
00 07
PANEL NOK:
00 04
The panels
detected are
displayed
The panels NOT
detected are
displayed