Cod. 97845
V06_17
INSTALLATION AND CONNECTIONS
Attach the rear part of the housing to the wall using the plugs and screws supplied. Pass the
cables through the bottom of the receiver. Connect the power cables to the terminals marked
in the mother board, as indicated. Fix the receiver front to the rear part using the screws
supplied.
OPERATING
The pilot lights are activated every 5 seconds to indicate the correct supply of power to the
equipment.
Upon receiving a code, the receiver checks whether it is in its memory, activating the
corresponding relay. The relay activation mode is selected in either impulse (monostable) or
ON/OFF using the Imp/Bies jumper (only with the relay 2).
PROGRAMMING
MANUAL PROGRAMMING
Press the receiver programming button for 1 sec. and an acoustic signal will be heard. The
receiver will enter standard programming (see table). If the receiver programming button is
held pressed down, the receiver will enter special programming, cyclically passing from one
configuration to the next. Once the programming configuration for the transmitter to be
registered has been chosen, send the code to be programmed by pressing the transmitter.
Every time a transmitter is programmed, the receiver will issue an acoustic signal for 0.5 sec.
After 10 seconds without programming or pressing the first two transmitter buttons, the
receiver will exit programming mode, issuing two acoustic signals of 1 sec. If upon
programming a transmitter the receiver memory is full, it will issue 7 acoustic signals of 0.5
sec. and exit programming.
Configuration of transmitter programming in the receiver.
Standard Programming (default option, the receiver is always configured on pluri-channel)
The relays are activated 1st relay by channel 1 and 2nd relay by channel
2 (3rd relay by channel 1 and 4th relay by channel 2)
By pressing any transmitter channel, relay 1 on the receiver will be
activated
By pressing any transmitter channel, relay 2 on the receiver will be
activated
By pressing any transmitter channel, the two relays will be activated at
the same time*
* If working in ON/OFF activation mode, relay 1 will act as impulse (monostable) and relay 2 as
ON/OFF. Therefore, on the first press relay 1 will close and open the contact and relay 2 will
only close. On the second, relay 1 will close and open the contact and relay 2 will open.
N.B.: Each transmitter can be configured independently on the receiver.
TOTAL RESET
In programming mode, the programming button is held down and the "MR" reset jumper is
bridged for 3 secs. The receiver will issue 10 short acoustic warning signals followed by others
at a faster pace to indicate that the operation has been successful. The receiver is now in
programming mode.
Special programming
6
Led R1
Led R2
Flashing
Flashing
ON
OFF
OFF
ON
ON
ON
1248123/1.0