4. Maintenance
To ensure optimum performance and lifetime:
– Protect the yoke supports and the yokes against corrosion, damage
and deformation. A perfect contact between the yoke and the
support is vital for optimum function.
– Protect the heater from water or very high humidity.
4.1 Fault finding
Most faults will cause an indication of the display as shown below.
Display
E 00 E
E 01 E
E 02 E
E 03 E
E 04 E
E 05 E
E 06 E
E 07 E
4.2 Transportation
Before transportation, secure top yoke properly. Use safety straps when
transporting by car or in a van.
4.3 Spare parts list TIH 240
Spare parts available on request.
14
Fault
Electronic failure
Electronic failure
Electronic failure
Overheating in the housing
Selected time/temperature
out of range
Temperature increase below
1 degree per 60 seconds
Temperature probe not
connected or defect
Current control defect
Action
Return to SKF for repair
Return to SKF for repair
Return to SKF for repair
Waiting for cooling down
Re-program
Check the probe connection
or change to TIME MODE
Check the probe
Return to SKF for repair
SKF TIH 240