S&P EDM-80L Manual De Instrucciones página 8

Extractor de aseos y baños
Ocultar thumbs Ver también para EDM-80L:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Operating and installation
instructions
Please check that your unit is in
perfect conditions when
unpackaging it, as any defect of
manufacturing is covered by the
SP guarantee.
Installation
Important: be sure to switch off
the power supply before
installing and making the
electrical connections
The EDM-80 L is particularly
suitable for ventilation of
bathrooms, toilets, showers, etc.
either discharging to outside, or
through individual ducts and
ducting systems, and has been
specially designed for fitting in the
same location as a standard
builders wall vent.
Before installation, remove the
front grille by loosening the fixing
screw (Fig. 2).
A circular hole approximately 100
mm Ø diameter must be made in
the wall or ceiling and the fan
spigot inserted into the hole,
fixing the fan casing by means of
the wall plugs and screws
supplied. Ensure that there are no
obstructions to the airflow is
discharge is to outside or into a
communal ventilation system.
When individual outlet ducting is
used, standard 100 mm Ø
diameter should be used.
Wiring
The EDM-80 L is suitable for
connection to a single phase
supply at the voltage and
frecuency indicated on the rating
plate. This appliance has double
(Class II) electrical insulation and
therefore does not require
earthing.
Connection terminals are situated
under the front cover.
There should be a double pole
isolating switch in the installation
(with a contacting opening of at
least 3 mm).
For surface wiring pass the cable
through cable gland as shown in
Fig. 5b (not as Fig. 5a) then under
the cable anchorage secure.
For recessed wiring, open
membrane in fan back plate, pass
cable through and secure with
cable anchorage.
8
loading